The steps to shutdown the telescope are somewhat the reverse of the Startup process- but greatly simplified. Knowledge of the Startup process are assumed in the steps below.
Do whatever last minute things you need to do on the computer and shut it down nicely.
NOTE: as a generally rule do not let it install updates especially when you are putting everything into lightning shutdown. Note that it wants updates in the Status Update.
Turn off the Large UPS by pressing the “power” button. Turn off small UPS, this requires pressing and holding for a moment.
Unplug both UPS's from the wall now that they are off.
In Warm room unplug the ethernet cable that gives service to Controller. This is to protect it from any lightning travelling through the ethernet cable (RIP Phillips in 2019).
Consider covering the Telescope and main computer desk with tarps if there is expected rain or snow in the forecast. The desk should be quite easy but the telescope can be a bit of a challenge. Another person (second presenter, program guest, Mountain Operations) is extremely helpful. Utilizing the Tarp Lofter 9000™ will make this much easier.