public:kitt_peak:bok_90:troubleshooting:proper_way_to_start_or_restart_the_filter_wheel_gui
Things you should do every time you need to start/restart the filter wheel GUI:
Make sure the telescope is at stow
Close out of the FW gui if running
Close galilserver if running
Turn off the 90prime system power switch
Wait 2 minutes
Turn on the 90prime system power switch, you should hear 3 loud beeps
Wait 2 minutes
Start galilserver
Start fw-gui
Unload filter if it says one is in the beam, wait for filter to unload.
Click “populate”
Wait 10 seconds
Click “populate done”
Click “read filters”
Wait for “wheel moving” to stop, takes about a minute
Click initialize filters
Wait for “wheel moving” to stop, takes about a minute
You should now be able to load and unload filters, if not call phone support