User Tools

Site Tools


vatt:what_is_new_at_vatt

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
vatt:what_is_new_at_vatt [2022/10/18 12:11]
paul
vatt:what_is_new_at_vatt [2023/06/08 08:34] (current)
paul [AOC 4k Monitors as of 2023-06-07]
Line 1: Line 1:
 ====== What's New at VATT ====== ====== What's New at VATT ======
 +
 +----
 +
 +===== Guide Box Y Axis as of December 2022 =====
 +
 +A new type of error has started showing its ugly head in mid-November. It usually starts with the Y axis of the 
 +guider camera's 3-axis translation stage. For example, the command is to move from 0 to +65. Motion stops at +35. 
 +
 +**Solution.** Cycle power on the MOXA serial-to-ethernet media converter: In the Dome, pull the power-over-ethernet cable (orange) out of the Moxa unit and plug it back in. In Control room, run ''Initialize'' and ''Reference'' from the user Secondary-and-Guider GUI.
  
 ---- ----
Line 22: Line 31:
 ''Scope MxRA'' and ''MxDEC''  ''Scope MxRA'' and ''MxDEC'' 
  
-The correct IP setup is:+The correct IP setup is loaded by default. Just for reference, it is:
  
 ''subnet    10.0.255.255''\\ ''subnet    10.0.255.255''\\
Line 31: Line 40:
  
  
-===== Temperature Data in TCS as of September 2022 =====+===== Temperature Data in TCS as of December 2022 =====
  
-The ''Air Temp'', ''Strut Temp'', ''Mirror Temp'', and ''Mirror Air Temp'' (the ''Thermal'' tab in ''TCSglue''may again be regarded as **reliable**. +The ''Air Temp'', ''Strut Temp'', ''Mirror Temp'', and ''Mirror Air Temp'' (the ''Thermal'' tab in ''TCSglue''must be regarded as **unreliable**. 
  
 :!::!::!: **Thermal shock is a 8-O danger m( to glass integrity :!::!: NEVER open the mirror cover if the mirror is more than 5°C warmer than ambient air** :!::!::!: :!::!::!: **Thermal shock is a 8-O danger m( to glass integrity :!::!: NEVER open the mirror cover if the mirror is more than 5°C warmer than ambient air** :!::!::!:
Line 41: Line 50:
 8-) First, run the thermal control system ([[vatt:vatt_neslab|NESLAB]] [in the silo] + cell fans [GUI] + TCSglue [GUI]) to bring the M1 temperature down at the beginning of the night, using the ''Set point'' mode. Then, during the night, leave the system running in the ''On'' mode. 8-) First, run the thermal control system ([[vatt:vatt_neslab|NESLAB]] [in the silo] + cell fans [GUI] + TCSglue [GUI]) to bring the M1 temperature down at the beginning of the night, using the ''Set point'' mode. Then, during the night, leave the system running in the ''On'' mode.
  
-Example. Sunset is at 19:30. At 17:00 TCSglue sees the ''Air Temp'' as 20°C, and the ''Mirror Temp'' as 14°C. The actual ambient temperature at 19:30 will be around 12°C. At 17:00 open the dome slit, and start the large dome fan to evacuate the accumulated hot air. Turn on [[vatt:vatt_neslab|NESLAB]] (in the silo) and the cell fans (control room with ''TCSglue''). At 18:00, activate the thermal control code, using a set point of 12°C. After about an hour, mirror temperature ought to be approaching the set point, bringing the temperature difference with respect to ambient within the safety limit (ΔT<5°C). For the remainder of the night, switch to the ''On'' mode (TCSglue [GUI], ''Thermal'' tab, ''On'' radio button). +Example. Sunset is at 17:30. At 16:30 TCSglue sees the ''Air Temp'' as 0°C, and the ''Mirror Temp'' as 1°C. The actual ambient temperature at 18:00 will be around -4°C. At 16:30 open the dome slit, and start the large dome fan to evacuate the accumulated warm air. Turn on [[vatt:vatt_neslab|NESLAB]] (in the silo) and the cell fans (control room with ''TCSglue''). Activate the thermal control code, using a set point of -4°C. After about an hour, mirror temperature ought to be approaching the set point, bringing the temperature difference with respect to ambient within the safety limit (ΔT<5°C). For the remainder of the night, turn off the thermal control system (TCSglue [GUI], ''Thermal'' tab, ''Off'' radio button; turn off [[vatt:vatt_neslab|NESLAB]] (in the siloand the cell fans using ''TCSglue'').  
 + 
 +Note that about 5-10 minutes after you turn off the thermal control system, there will be a significant jump in the ''Air Temp'' and ''Strut Temp'' values and a slightly smaller jump in the ''Mirror Temp'' and ''Mirror Air Temp''. A few cycles later the values will stabilize and become realistic.
  
 ---- ----
Line 49: Line 60:
 You may use a new ''Watchman'' wifi device for independent measurements of temperature and humidity in the dome. It is plugged in (it needs 5V power) by the flood lamp and the dome cameras (legacy and HikVision). This is "dirty" power, which means that the device is available during lightning shutdowns. You may use a new ''Watchman'' wifi device for independent measurements of temperature and humidity in the dome. It is plugged in (it needs 5V power) by the flood lamp and the dome cameras (legacy and HikVision). This is "dirty" power, which means that the device is available during lightning shutdowns.
  
-Open the link [[http://10.0.3.20:42778/d9e3ce041522&Stats]] in any browser. +Open the link [[http://10.0.3.20/d9e3ce041522&Stats]] or [[http://10.0.3.20:42778/d9e3ce041522&Stats]] in any browser. 
  
 Another unit (temperature, humidity, pressure) is in the enclosed opening at the base of the pier; go to [[http://10.0.3.21/52c4b2062022&Stats]] Another unit (temperature, humidity, pressure) is in the enclosed opening at the base of the pier; go to [[http://10.0.3.21/52c4b2062022&Stats]]
  
-And a third unit (temperature, humidity; no display) is <del>in the basement pump room</del> by the grill on the SW porch; go to [[http://10.0.3.22/d729ba062022&Stats]]+And a third unit (temperature, humidity; no display) is dead <del>in the basement pump room</del> <del>by the grill on the SW porch</del>; go to [[http://10.0.3.22/d729ba062022&Stats]]
  
  
 An hourly log is available in the cloud. Go to [[https://pp-code.azurewebsites.net/]], logging in as pgabor@arizona.edu with the usual VATT observer password. You will find a button marked ''Click here for your Watchman logs'' prominently displayed. Click on it. This will take you to a list of devices. Click on the device name (''VATT_dome'') to see its logs. An hourly log is available in the cloud. Go to [[https://pp-code.azurewebsites.net/]], logging in as pgabor@arizona.edu with the usual VATT observer password. You will find a button marked ''Click here for your Watchman logs'' prominently displayed. Click on it. This will take you to a list of devices. Click on the device name (''VATT_dome'') to see its logs.
 +
 +Logs every minute are available through \\
 +''ssh vattobs@vatt.as.arizona.edu -p 42069'' (usual ''vattobs'' password)\\
 +''cd /home/mtnops/.mtnops/logs''\\
 +The relevant files are ''10.0.3.20:42778.watchman.log'', and ''10.0.3.21:80.watchman.log''.
 +
 +You can download the logs using, e.g., 
 +
 +''scp -P 42069 vattobs@vatt.as.arizona.edu:/home/mtnops/.mtnops/logs/10.0.3.21:80.watchman.log <your-local-dir>/watchman.log''
  
 ---- ----
Line 67: Line 87:
  
  
-===== Samsung Galaxy Tablet for Skype and Zoom as of June 2022 =====+===== Samsung Galaxy Tablet for Skype and Zoom as of January 2023 =====
  
-The ''Skype'' app no longer appears to function on the Samsung Galaxy Tablet (log in impossible). :-( Please use your cell phone for ''Skype'' Use the account ''vatt.telescope'' with the usual VATT observer password.+The Samsung Galaxy Tablet is now officially dead. Before the hardware gave up, the ''Skype'' app became dysfunctional (log in impossible). :-( 
  
-The tablet still works well with the ''Zoom'' app. Zoom does not require you to log in. When you open the ''Zoom'' app, simply ''join'' a meeting (by typing in meeting's 10 or 11-digit numerical identifier) and set your participant name according to your pleasure. +Please use your cell phone for ''Skype'' Use the account ''vatt.telescope'' with the usual VATT observer password. 
 + 
 +You may also use Zoom, which does not require you to log in. When you open the ''Zoom'' app, simply ''join'' a meeting (by typing in meeting's 10 or 11-digit numerical identifier) and set your participant name according to your pleasure.  
 + 
 +Mountain Operations favor using a Zoom session for trouble shooting telescope issues. It bears the poetic name //Oasis// or MOO (Mountain Ops Oasis): ''583 222 052''
  
 8-) For your reference, the recurring ''Zoom'' meeting with the LBT's TO (telescope operator), support astronomer, and users is ''886 440 6140''. 8-) For your reference, the recurring ''Zoom'' meeting with the LBT's TO (telescope operator), support astronomer, and users is ''886 440 6140''.
Line 88: Line 112:
 ---- ----
  
-===== Guider Camera as of February 2022 ===== 
  
-Only one guider camera is available. It is used for all instruments. Check that the PHD2 profile contains the correct IP setup:+===== Oil Chillers as of December 2022 =====
  
-''subnet    10.0.255.255''\\ +Both chillers are fully functionalThe system is set to ''AUTO'' mode
-''IP:port   10.0.3.12:2571'' +
- +
----- +
- +
-===== Oil Chillers as of February 2022 ===== +
- +
-Chiller 1 is out of order. Use chiller 2.  +
- +
-Startup: +
-  * By the north wall of the basement pump room: +
-    * Turn on the building and pier fans +
-  * At the cabinet at your left when exiting the elevator:  +
-    * Turn on ''Step 1'' (pulling out mushroom button) +
-  * At the oil tank by the south wall of the basement pump room: +
-    * Make sure both chiller 1 and 2 controls are in ''Manual'' mode +
-    * Turn on Chiller 2 (push button) +
-  * Back at the cabinet at your left when exiting the elevator:  +
-    * Turn on ''Step 2'' +
- +
-Shutdown:+
  
-  * At the cabinet at your left when exiting the elevator:  +Remember that you can check the oil temperature and the chiller current using the  
-    * Turn off ''Step 2'' +Axis 214 PTZ (pan-tilt-zoomcamera in the basement.\\ 
-  * At the oil tank by the south wall of the basement pump room: +http://vatt.as.arizona.edu:42823\\ 
-    * Turn off Chiller 2 (push button) +http://10.0.2.23
-  * Back at the cabinet at your left when exiting the elevator:  +
-    * Turn off ''Step 1'' (pushing in mushroom button) +
-  * By the north wall of the basement pump room+
-    * Turn off the building and pier fans+
  
 ---- ----
Line 172: Line 171:
 ---- ----
  
-===== AOC 4k Monitors as of 2020-10-01 =====+===== AOC 4k Monitors as of 2023-06-07 =====
  
 These monitors are nice. These monitors are nice.
Line 185: Line 184:
  
 The AOC 4k monitors are U4308V.  {{ :vatt:aoc_product_manual_u4308v_english.pdf |Here is the manual.}} The AOC 4k monitors are U4308V.  {{ :vatt:aoc_product_manual_u4308v_english.pdf |Here is the manual.}}
 +
 +Note that the ''Input Select'' in the monitor's main menu must be set to ''Auto'' (see p. 21 of the manual). When this is the case, the monitor reliably finds the source (HP Thin Client or a laptop attached to the ''HDMI 2'' port). :!: Make sure that the ''Input Select'' is set to ''Auto'' :!:
 +Also note that the multipurpose button can be used (pushing it upwards) to activate a simple source selection menu (see p. 12 of the manual). When you do use the simple source selection menu to select a source, however, go back to the main menu and make sure that the ''Input Select'' is set to ''Auto'' because selecting a source with the small menu changes the settings in the main menu.
 +
 +Note that there is a power switch at the bottom of the monitor next to the socket for the power cord.
 ---- ----
  
vatt/what_is_new_at_vatt.1666120304.txt.gz · Last modified: 2022/10/18 12:11 by paul