-^ ^ Warm Shutdown / Dec 22019 / P Gabor ^ ✔✘ ^+^ ^ Warm Shutdown / July 82021 / P Gabor, D Brown ^ ✔✘ ^
 |Control room|Turn on dome floodlight (left of the SW balcony door)| | |Control room|Turn on dome floodlight (left of the SW balcony door)| |
 |Control room|Turn off the main dome fan (red button on a strip to the right of the SW balcony door)| | |Control room|Turn off the main dome fan (red button on a strip to the right of the SW balcony door)| |
 |Control room|TCSglue main window: STOW; watch telescope move| | |Control room|TCSglue main window: STOW; watch telescope move| |
-|Control room|TCSglue main window: Enable derotator tracking (if disabled)| | 
 |Control room|MOUNT CONTROL tab: Disable drives (listen for air being released from brake)| | |Control room|MOUNT CONTROL tab: Disable drives (listen for air being released from brake)| |
 |Control room|MOUNT CONTROL tab: Close mirror cover (listen for sound of proper operation)| | |Control room|MOUNT CONTROL tab: Close mirror cover (listen for sound of proper operation)| |
Line 11: Line 10:
 |Control room|XEPHEM: main window, ''File'' pull-down menu: select ''Quit'' and answer in the affirmative that you wish to exit XEPHEM| | |Control room|XEPHEM: main window, ''File'' pull-down menu: select ''Quit'' and answer in the affirmative that you wish to exit XEPHEM| |
 |Control room|PHD2: click the ''Connect'' icon (looks like a male USB connector) on the main task bar; click ''Disconnect'' camera and mount; exit PHD2| | |Control room|PHD2: click the ''Connect'' icon (looks like a male USB connector) on the main task bar; click ''Disconnect'' camera and mount; exit PHD2| |
 +|Control room|Secondary and Guidebox GUI: Secondary (top part): copy values to trouble report, turn off autocollimation, disconnect; Guidebox (bottom part): disconnect; kill the terminal in which the ''Secondary and Guidebox INDI'' is running| |
 |Control room|INDI: find the terminal in which INDI is running and kill it| | |Control room|INDI: find the terminal in which INDI is running and kill it| |
-|Control room|Secondary and Guidebox GUI: Secondary (top part)copy values to trouble report, turn off autocollimation, disconnect; Guidebox (bottom part): disconnect; kill GUI| | +|Control room|THERMAL tabradio button ''OFF''| | 
-|Control room|THERMAL tab: radio button "OFF"| |+|Control room|CONTROL tab: cell fans ''OFF'' | |
 |Silo 2nd lvl|NESLAB: Simultaneously: toggle fron panel ON/OFF switch to "OFF" & slowly lower manual valve lever| | |Silo 2nd lvl|NESLAB: Simultaneously: toggle fron panel ON/OFF switch to "OFF" & slowly lower manual valve lever| |
-|TCS room|Flip the switch on the quad to turn M1 cell fans off. This will also turn off a night light connected in parallel to indicate that M1 cell fans are now powered down.| | 
 |TCS room|Toggle power switches "OFF": AZ, EL, DEROTATOR & DOME amplifiers| | |TCS room|Toggle power switches "OFF": AZ, EL, DEROTATOR & DOME amplifiers| |
 |TCS room|M2 PI Controller: turn off| | |TCS room|M2 PI Controller: turn off| |