This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision | ||
vatt:vatt_warm_shutdown_checklist [2018/11/14 01:12] paul |
vatt:vatt_warm_shutdown_checklist [2022/04/14 05:36] (current) paul |
||
---|---|---|---|
Line 1: | Line 1: | ||
- | ^ ^ Warm Shutdown / Nov 13, 2018 / P Gabor ^ ✔✘ ^ | + | ^ ^ Warm Shutdown / July 8, 2021 / P Gabor, D Brown ^ ✔✘ ^ |
|Control room|Turn on dome floodlight (left of the SW balcony door)| | | |Control room|Turn on dome floodlight (left of the SW balcony door)| | | ||
|Control room|Turn off the main dome fan (red button on a strip to the right of the SW balcony door)| | | |Control room|Turn off the main dome fan (red button on a strip to the right of the SW balcony door)| | | ||
|Control room|TCSglue main window: STOW; watch telescope move| | | |Control room|TCSglue main window: STOW; watch telescope move| | | ||
- | |Control room|TCSglue main window: Enable derotator tracking (if disabled)| | | ||
|Control room|MOUNT CONTROL tab: Disable drives (listen for air being released from brake)| | | |Control room|MOUNT CONTROL tab: Disable drives (listen for air being released from brake)| | | ||
|Control room|MOUNT CONTROL tab: Close mirror cover (listen for sound of proper operation)| | | |Control room|MOUNT CONTROL tab: Close mirror cover (listen for sound of proper operation)| | | ||
Line 10: | Line 9: | ||
|Control room|XEPHEM: | |Control room|XEPHEM: | ||
|Control room|XEPHEM: | |Control room|XEPHEM: | ||
- | |Control room|Kill VATT Guider APP| | | + | |Control room|PHD2: click the '' |
- | |Control room|[[vatt: | + | |Control room|Secondary |
- | |Control room|THERMAL tab: radio button | + | |Control room|INDI: find the terminal in which INDI is running |
+ | |Control room|THERMAL tab: radio button | ||
+ | |Control room|CONTROL tab: cell fans '' | ||
|Silo 2nd lvl|NESLAB: Simultaneously: | |Silo 2nd lvl|NESLAB: Simultaneously: | ||
- | |TCS room|Unplug M1 cell fans {{ : | ||
|TCS room|Toggle power switches " | |TCS room|Toggle power switches " | ||
|TCS room|M2 PI Controller: turn off| | | |TCS room|M2 PI Controller: turn off| | | ||
Line 25: | Line 25: | ||
|Dome|**VATT 4k CCD Imager only:** place LN2 dewar under telescope, connect hose and charge camera dewar with LN2| | | |Dome|**VATT 4k CCD Imager only:** place LN2 dewar under telescope, connect hose and charge camera dewar with LN2| | | ||
|Dome|**VATT 4k CCD Imager only:** fill out camera LN2 log sheet| | | |Dome|**VATT 4k CCD Imager only:** fill out camera LN2 log sheet| | | ||
- | |Dome|Power " | + | |Dome|// |
|Dome|Close finder telescope objective cover| | | |Dome|Close finder telescope objective cover| | | ||
|Dome|Turn off power supply of finder telescope camera (on top of box on South side of East fork)| | | |Dome|Turn off power supply of finder telescope camera (on top of box on South side of East fork)| | |