| Warm Shutdown / Jan 27, 2018 / P Gabor | ✔✘ |
Control room | Turn on dome floodlight (left of the SW balcony door) | |
Control room | Turn off the main dome fan (red button on a strip to the right of the SW balcony door) | |
Control room | TCSglue main window: STOW; watch telescope move | |
Control room | MOUNT CONTROL tab: Disable drives (listen for air being released from brake) | |
Control room | MOUNT CONTROL tab: Close mirror cover (listen for sound of proper operation) | |
Control room | MOUNT CONTROL tab: Close dome shutter (slit) (listen for sound of proper operation) | |
Control room | TSCglue main window: stop dome tracking (toggling the button) | |
Control room | XEPHEM: SKY VIEW WINDOW: “Telescope” menu: “Configure” window: Radio button: Telecscope “running”: toggle off with mouse click | |
Control room | XEPHEM: Load data memory window: KILL (“X” out) | |
Control room | Quit Xephem (or exit) | |
Control room | Warning box/button: dismiss | |
Control room | VATT Guider APP: “Camera” tab: stop | |
Control room | Kill VATT Guider APP | |
Control room | New Secondary GUI: copy values to trouble report, turn off autocollimation, shut down connection and GUI | |
Control room | THERMAL tab: radio button “OFF” | |
Silo 2nd lvl | NESLAB: Simultaneously: toggle fron panel ON/OFF switch to “OFF” & slowly lower manual valve lever (to minimize vibration) | |
Control room | MOUNT CONTROL tab: Turn cell fans “OFF” | |
TCS room | Toggle power switches “OFF”: AZ, EL, DEROTATOR & DOME amplifiers | |
TCS room | M2 PI Controller: turn off | |
Basement | Turn off building & pier fans | |
Basement | STEP TWO (labeled as such): Rotate pumps switch counterclockwise to “OFF” | |
Basement | STEP ONE (labeled as such): Push in red switch, upper left corner of control box | |
Dome | Engage stow pins | |
Dome | Connect camera ground wire | |
Dome | Place camera fill dewar under telescope, connect hose and charge dewar with LN2 | |
Dome | Fill out camera LN2 log sheet | |
Dome | Power “OFF” SBIG guider camera power supply (on guider arm mount) | |
Dome | Close finder telescope objective cover | |
Dome | Turn off power supply of finder telescope camera (on top of box on South side of East fork) | |
Dome | Dome vent registers: leave OPEN if weather is expected to stay good, otherwise CLOSE | |
Dome | Unplug power to dome shutter | |
Dome | Dome short can stay “OUT” if weather is expected to remain good, otherwise “IN” | |
Dome | Dewar can stay in place during the day | |
Control room | Turn OFF remaining TV feed monitors | |
Control room | Complete and submit Trouble Report | |
Control room | Power down Xterm monitors (they do not sleep automatically) | |