Current instruments and computing equipment available at the Vatican Advanced Technology Telescope are:
- A replacement STA0500A back illuminated 4K CCD, ITL serial number 8301, was installed March 2017, and updated 26 January 2018. - It is similar to the September 2007 one, including its QE. - Pixels: 4096×4096, 15×15 microns - Gain:1.9 e/DN - Full well: ADC limited (65k DN) = ~120,000 electrons unbinned - Noise: ~3.9 electrons - Photon Transfer Curve - Gain Curve - FOV: 12.5 arcmin square - pixel scale: 0.188 arcsec/pixel - wavelength range: 300 - 1000 nm, peak 96% at 450 nm - Preamplifiers added October 2008 inside the dewar. These give faster readout and lower noise.
ITL Serial Number 8228 2688x512 pixels, 15x15 microns Detector operating temperature -110C Gain: 1.3 e/DN with setting 10; 2.6 e/DN with setting 5 Full well, both gains: ADC limited (65k DN) = 85,000 or 170,000 electrons Noise: 3.4 electrons (3.2 in overscan region) QE Curve
- provides interface to derotator for all the above instruments. - effective back focal distance, from guide box to focal surface, is 2.000“. - contains two filter wheels, each holding four 3.48” square filters. Adapters to accommodate 2“ and 3” square filters are available. - UBVRI, uvby, Vilnius, Sloan, ECAS, and Order Blocking filters are currently provided. - integrating sphere with continuum and calibration lamps.