public:sunnyside:general_information [2020/04/08 14:53]
mel created
public:sunnyside:general_information [2020/04/08 15:17] (current)
mel
Line 1: Line 1:
 =====Sunnyside Mirror Coating Procedure===== =====Sunnyside Mirror Coating Procedure=====
- 
  
  
 ====Sunnyside 2m chamber description==== ====Sunnyside 2m chamber description====
 +    The vacuum chamber diameter: 84” I.D
 +    The vacuum chamber height: 12’ (13’ including hemispherical bottom).
 +    The chamber has one filament ring 71.75” diameter (center of filaments).
 +    The chamber wall to the center of the filaments is 6.125”.
 +    The optimum placement of the surface of the mirror in the chamber is 19” below the chamber lid.
 +    The top of the filaments to the edge of the mirror is 34” (vertical measurement - 72” diameter mirror).
 +    The top of the filaments to the chamber lid is 53”.
 +    The mirrors are held from the chamber lid, the coated surface faces down.
 +    There is one ring of 36 filaments located near the periphery of the chamber, below the mirror.
 +    The filaments are made from 3 strand twisted tungsten wire (individual wire size 0.020”), 6 coils per filament, coiled section of filament 2.5” long, coil diameter 0.44” O.D., overall length of tungsten wire 12.625”.
 +    Deposition material is aluminum, 99.999% purity, 1mm diameter wire, 1.25” or 1.375” long, folded twice, placed on the bottom of each filament loop, total of 216 pieces of aluminum.
 +    The tungsten filaments can be used for two or three shoots before they need to be replaced.
 +    Mechanical pump; Kinney KDH 250 rotary piston pump, pumping speed 248 (cfm)
 +    Roots Blower pump; Kinney KMBV 1300, pumping speed 1300 (cfm)
 +    (2) Diffusion pumps; Kinney KDP-32 (32” diameter) pumping speed 31000 l/s (baffled)
 +    Holding pump; Stokes Microvac 148-H9, pumping speed 40 (cfm)
 +    Rough vacuum pressure is measured with Granville-Phillips Series 275 controllers with Convectron gauge sensors.
 +    High vacuum pressure is measured with Granville-Phillips Series 270 controllers with Bayard-Alpert Series 274 ionization gauges.
 +    The deposition rate and total thickness are measured by a Maxtek TM-100 R, 6.0 MHz quartz crystal microbalance.
 +
 +[[.:Sunnyside Chamber Lid Drawings]]
  
-  * The vacuum chamber diameter is 84” I.D 
-  * The vacuum chamber height is 12’ (13’ including hemispherical bottom). 
-  * The chamber has one filament ring 71.75” diameter (center of filaments). 
-  * The chamber wall to the center of the filaments is 6.125”. 
-  * The optimum placement of the surface of the mirror in the chamber is 19” below the chamber lid. 
-  * The top of the filaments to the edge of the mirror is 34” (vertical measurement - 72” diameter mirror). 
-  * The top of the filaments to the chamber lid is 53”. 
-  * The mirrors are held from the chamber lid, the coated surface faces down. 
-  * There is one ring of 36 filaments located near the periphery of the chamber, below the mirror. 
-  * The filaments are made from 3 strand twisted tungsten wire (individual wire size 0.020”), 6 coils per filament, coiled section of filament 2.5” long, coil diameter 0.44” O.D., overall length of tungsten wire 12.625”. 
-  * Deposition material is aluminum, 99.999% purity, 1mm diameter wire, 1.25” or 1.375” long, folded twice, placed on the bottom of each filament loop, total of 216 pieces of aluminum. 
-  * The tungsten filaments can be used for two or three shoots before they need to be replaced. 
-  * Mechanical pump; Kinney KDH 250 rotary piston pump, pumping speed 248 (cfm) 
-  * Roots Blower pump; Kinney KMBV 1300, pumping speed 1300 (cfm) 
-  * (2) Diffusion pumps; Kinney KDP-32 (32” diameter) pumping speed 31000 l/s (baffled) 
-  * Holding pump; Stokes Microvac 148-H9, pumping speed 40 (cfm) 
-  * Rough vacuum pressure is measured with Granville-Phillips Series 275 controllers with Convectron gauge sensors. 
-  * High vacuum pressure is measured with Granville-Phillips Series 270 controllers with Bayard-Alpert Series 274 ionization gauges. 
-  * The deposition rate and total thickness are measured by a Maxtek TM-100 R, 6.0 MHz quartz crystal microbalance. 