Cold Start Power Up Sequence

Procedure for coming out of lightning shutdown or checking out the telescope and instrument.


Dome

  1. Dome encoder cable over entry door

West side of blue yoke, declination axis

  1. dec encoder
  2. dec motor
  3. dec tac

West side of base flange

  1. Finder scope lamp power (for reticle)

East side of base flange

  1. Limit cable
  2. Index sensor cable

Inside the south pier

  1. From outlet box #5
    1. Power cord running to power strip inside blue rack
    2. Power cord running to power strip mounted to south pier
    3. Power cord running to index meter box
  2. Black rectangle cable connection laying inside
    1. NOTE: Two cables plugged into one another that have black connectors
  3. Index meter cable
    1. NOTE: Connects up underneath backside of index meter box

RA Axis

  1. RA encoder on west side
  2. RA motor cable on east side
  3. RA tachometer cable on east side

Backside of blue rack

  1. Silver outlet box
    1. Mux power plug
    2. Bus extender cable
    3. Bus BNC
  2. Bus extender
    1. Bus cable
      1. NOTE: There is a black screw keeping cable in place.
  3. Backside of dome box
    1. #4 paddle
    2. #2 bus extender cable
    3. Dome encoder
    4. DEC encoder cable
    5. RA encoder cable
  4. Backside of stepper box
    1. Gate out BNC

—-

Control Room

Backside of blue control rack

Bottom of rack

  1. #5 TTL mono dome
  2. #3 stepper motor control
  3. #2 computer manual to dome and telescope control
  4. #1 single paddle control to old paddle

FORTH computer backside

  1. NOTE: If 2MASS is on the telescope there is nothing to disconnect. If another instrument is on the telescope then disconnect Com2 cable.

Silver outlet box

  1. Bus BNC
  2. Power supply cable
  3. Power supply cable

Backside of Rack #1

  1. PC splitter box
    1. “From dome” silver cable
  2. Video monitor
    1. Video input BNC cable
  3. TV offset guide control backside
    1. Round connector
  4. Focus panel backside
    1. Focus cable on left hand side
      1. NOTE: Easy to miss
  5. Chop box
    1. Large round connector cable
    2. Transducer BNC