CASS (B&C, WIFIS, SCC) Lightning Shutdown
Complete a “Normal Shutdown” if you have not done so already.
Control Room
Turn off upper dome power
Turn off dome motor power
At the Operators Console:
Shutdown TCS computer
Shutdown guider computer
Turn IIS switch to OFF
Turn Dome switch to MANUAL
Turn off console
Push in emergency stop button on console
Unplug dome mic if in use next to AED
Observers Workstation
Shutdown AzCam program, shutdown Azcam computer (BOKCCD1) from start menu, and shutdown AzCam Xterm
Shutdown programs on Bart, shutdown Bart from Start Menu, and Bart Xterm
Shutdown weather computer
Electronics Computer Rack Area
Using the KVM switch make sure all computers in the rack are off:
Shut down Bokaux computer
Turn off flat field lamp controller if in use
Turn off printer
Turn off (2) UPS units in bottom of the rack
Note: The CONTROL ROOM UPS also powers the Operators Console, make sure everything in it is turned off first.
Warm Room Cable Closet
Unplug three plugs with red tape on your right as you enter the door down low
Unplug 1 twist lock plug with red tape west wall
Unplug GPS Ethernet cable, B&C cable and power cable on west wall
Second Floor Pier Room
Shutoff UPS in rack and unplug
Second Floor Office
Unplug power strip from wall
Disconnect phone line from fax machine
There is a computer tower that sits to the left of the desk. If on, turn off by pushing the power button.
90Prime Lightning Shutdown
Complete a “Normal Shutdown” if you have not done so already
Instrument
Unload filter from filter wheel
Turn off “90 Prime CCD” and “90 Prime System” rotary switches on black computer rack
Control Room
Turn off upper dome power
Turn off dome motor power
At the Operators Console:
Shutdown TCS computer
Shutdown guider computer
Turn IIS switch to OFF
Turn Dome switch to MANUAL
Turn off console
Push in emergency stop button on console
Unplug dome mic if in use next to AED
Observers Workstation
Shutdown AzCam program, shutdown Azcam computer (BOKCCD2) from start menu, and shutdown AzCam Xterm
Shutdown programs on Bart, shutdown Bart from Start Menu, and Bart Xterm
Shutdown weather computer
Electronics Computer Rack Area
Using the KVM switch make sure all computers in the rack are off
Shut down bokaux computer
Turn off flat field lamp controller if in use
Turn off printer
Turn off (2) UPS units in bottom of the rack
* Note: The CONTROL ROOM UPS also powers the Operators Console, make sure everything in it is turned off first.
Warm Room Cable Closet
Unplug three plugs with red tape on your right as you enter the door down low
Unplug 1 twist lock plug with red tape west wall
Unplug GPS Ethernet cable, B&C cable and power cable on west wall
Second Floor Pier Room
Shutoff UPS in rack and unplug
Second Floor Office
Unplug power strip from wall
Disconnect phone line from fax machine
There is a computer tower that sits to the left of the desk. If on, turn off by pushing the power button.
Cold Start up- Coming out of Lightning Shutdown
Second Floor Office
Plug in power strip
Connect phone line to fax machine
Turn on the computer tower to the left of the desk by pressing the power button.
Second Floor Pier Room
Plug in UPS and turn on
Warm Room Cable Closet
Plug in three plugs with red tape on your right as you enter the door down low
Plug in 1 twist lock plug with red tape west wall
Plug in GPS Ethernet cable, B&C cable and power cable on west wall