User Tools

Site Tools


phd2:phd2_guiding_abbreviated

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Next revision
Previous revision
phd2:phd2_guiding_abbreviated [2018/10/05 16:02]
cjohnson created
phd2:phd2_guiding_abbreviated [2018/11/08 11:38] (current)
tgolota
Line 9: Line 9:
 (*) When using VATT4k and GUFI, these motors move the two filter wheels for the science camera, the guider camera's filter wheel, the guider camera's 3-axis translation stage, and the stage carrying the center mirror and the U mirror. (*) When using VATT4k and GUFI, these motors move the two filter wheels for the science camera, the guider camera's filter wheel, the guider camera's 3-axis translation stage, and the stage carrying the center mirror and the U mirror.
  
-  * start indiserver+  * **Start indiserver**:
     * click the indiserver icon on the desktop     * click the indiserver icon on the desktop
     * (a terminal window should appear)     * (a terminal window should appear)
-  * start phd2 guiding+  * **Start phd2 guiding:**
     * click the PHD2 icon on the desktop     * click the PHD2 icon on the desktop
     * (the PHD2 application should appear)     * (the PHD2 application should appear)
-  * configure phd2+  * **Configure phd2:**
     - in the ''Main tool bar'', click icon that looks like a usb male connector     - in the ''Main tool bar'', click icon that looks like a usb male connector
        * (''connect equipment'' window should appear)        * (''connect equipment'' window should appear)
Line 29: Line 29:
           * offset guider (used with imagers) ip:port : 10.0.3.14:2571; slit plate guider (used with VATTspec): 10.0.3.12:2571           * offset guider (used with imagers) ip:port : 10.0.3.14:2571; slit plate guider (used with VATTspec): 10.0.3.12:2571
     - click the ''connect'' button in the ''Connection'' field     - click the ''connect'' button in the ''Connection'' field
-      * (after a few seconds, a bunch of new fields and tabs should appear.)  +      * (after a few seconds, a bunch of new fields and tabs should appear)   
 +      * (The message "[ERROR] Model is not supported by the INDI Apogee driver" may mean that the camera is not powered up.)
     - near the bottom of the window, turn on the cooler     - near the bottom of the window, turn on the cooler
     - IF YOU ARE GOING TO BE AUTOGUIDING:     - IF YOU ARE GOING TO BE AUTOGUIDING:
-        * click on the "INDI-VATT-GUIDE" TAB+        * click on the "VATT-GUIDE-INDI" TAB
         * click "Connect"         * click "Connect"
         * (a UT clock should appear and begin incrementing.)         * (a UT clock should appear and begin incrementing.)
Line 43: Line 44:
           * (the button should now say ''Disconnect'')           * (the button should now say ''Disconnect'')
     - click ''Close'' in the ''Connect Equipment'' window     - click ''Close'' in the ''Connect Equipment'' window
-    - In the ''Main tool bar'' (it may be positioned anywhere in the window),  +    - (OPTIONAL) Set up automatic frame capture
-      * click the ''Advanced setup'' (brain icon) button (second from the right); a new window should appear. +      * Select the ''Global'' tab, it is part of 'advanced setup' (the brain symbol)
-    - Set binning to the allowed maximum of 8x8:  +
-      * Select the ''Camera'' tab, +
-      * in the group ''Camera-specific properties'', set binning to 8 (pull down selector). +
-      * [Note. Ostensibly, binning can be set via ''INDI options'' as NxM where N and M may take any value you wish.  This feature does not work. Binning can really be set only via "brain button.] +
-    - IF YOU WILL NOT BE AUTOGUIDING: Disable mount guide output: +
-      * Select the ''Guiding'' tab, +
-      * in the group ''Shared parameters'' disable //mount guide output// (uncheck the box); ''Guide   output DISABLED'' should appear in the lower left of the main window. This should prevent PHD2   accidentally interfering, e.g., with the PEPSI guider. +
-    - Set up automatic frame capture: +
-      * Select the ''Global'' tab,+
       * check ''Enable diagnostic image logging'', then       * check ''Enable diagnostic image logging'', then
       * in the group ''Save Guider Images'' check ''Until this count is reached'', and       * in the group ''Save Guider Images'' check ''Until this count is reached'', and
Line 61: Line 53:
       * The directory ''/home/vattobs/PHD2/PHD2_CameraFrames...'' is automatically created for the session.       * The directory ''/home/vattobs/PHD2/PHD2_CameraFrames...'' is automatically created for the session.
       * If you need to capture more than 100 images, make a renamed copy of the session directory; new   //fits// files should start populating the original sesson directory.       * If you need to capture more than 100 images, make a renamed copy of the session directory; new   //fits// files should start populating the original sesson directory.
-  * Start Imaging+  * **Move U-Mirror** 
 +     - Use the Secondary App to move the Guide Camera stage so that it is on the U-Mirror.  
 +  * **Start Imaging:**
     - in the bottom left of the PHD2 window there is a button with 2 arrows forming a circle. Click that button.     - in the bottom left of the PHD2 window there is a button with 2 arrows forming a circle. Click that button.
     - the button should gray out, the stop sign button should turn red, and images should start appearing     - the button should gray out, the stop sign button should turn red, and images should start appearing
 +  * **Start Guiding:**
 +    - change the exposure time setting and contrast slider to find an appropriate guide star.
 +    - Click on the guide star
 +    - click on the circular icon i the tool bar that looks like a target
  
   Offset Guider Stage   Offset Guider Stage
  
 Note: All numbers are GUI units. The travel limits are accurate but the diagram is only an approximation. Note: All numbers are GUI units. The travel limits are accurate but the diagram is only an approximation.
-{{ :phd2:offset_guider_stage.gif?direct |}}+{{ :phd2:offset_guider_stage_2.gif?direct |}}
phd2/phd2_guiding_abbreviated.1538780552.txt.gz · Last modified: 2018/10/05 16:02 by cjohnson