Cold Start (from lightning shutdown)

  1. Turn on main power at the white breakers on the south west side of the building.
  2. Plug in Dome Shutter motor on the west wall.
  3. Turn dome power on at the telescope power box (middle black button)
  4. Open Shutter using shutter control box on the south wall.
  5. unplug shutter motor (or dome won't move)
  6. Confirm TCS/servo mechanism is plugged in
  7. Turn Telescope motor on at telescope power box
  8. Power on TCS console/GUI computer.
  9. Switch Telescope control to remote on the telescope power box.
  10. While computer boots, remove the telescope cover using the handles on the side of the telescope. 1)
  11. Using TCS GUI slew telescope to telescope cover access position to remove finder scope cover Az= 0 alt=11.2)
1)
Open the south side first.
2)
This will aim the Telescope towards the North wall.