^ ^ Warm Shutdown / Jan 27, 2018 / P Gabor ^ ✔✘ ^ |Control room|Turn on dome floodlight (left of the SW balcony door)| | |Control room|Turn off the main dome fan (red button on a strip to the right of the SW balcony door)| | |Control room|TCSglue main window: STOW; watch telescope move| | |Control room|MOUNT CONTROL tab: Disable drives (listen for air being released from brake)| | |Control room|MOUNT CONTROL tab: Close mirror cover (listen for sound of proper operation)| | |Control room|MOUNT CONTROL tab: Close dome shutter (slit) (listen for sound of proper operation)| | |Control room|TSCglue main window: stop dome tracking (toggling the button)| | |Control room|XEPHEM: SKY VIEW WINDOW:  "Telescope" menu: "Configure" window: Radio button: Telecscope "running": toggle off with mouse click| | |Control room|XEPHEM: Load data memory window: KILL ("X" out)| | |Control room|Quit Xephem (or exit)| | |Control room|Warning box/button: dismiss| | |Control room|VATT Guider APP: "Camera" tab: stop| | |Control room|Kill VATT Guider APP| | |Control room|[[vatt:hexapod|New Secondary GUI]]: copy values to trouble report, turn off autocollimation, shut down connection and GUI| | |Control room|THERMAL tab: radio button "OFF"| | |Silo 2nd lvl|NESLAB: Simultaneously: toggle fron panel ON/OFF switch to "OFF" & slowly lower manual valve lever (to minimize vibration)| | |Control room|MOUNT CONTROL tab: Turn cell fans "OFF"| | |TCS room|Toggle power switches "OFF": AZ, EL, DEROTATOR & DOME amplifiers| | |TCS room|M2 PI Controller: turn off| | |Basement|Turn off building & pier fans| | |Basement|STEP TWO (labeled as such): Rotate pumps switch counterclockwise to "OFF"| | |Basement|STEP ONE (labeled as such): Push in red switch, upper left corner of control box| | |Dome|Engage stow pins| | |Dome|Connect camera ground wire| | |Dome|Place camera fill dewar under telescope, connect hose and charge dewar with LN2| | |Dome|Fill out camera LN2 log sheet| | |Dome|Power "OFF" SBIG guider camera power supply (on guider arm mount)| | |Dome|Close finder telescope objective cover| | |Dome|Turn off power supply of finder telescope camera (on top of box on South side of East fork)| | |Dome|Dome vent registers: leave OPEN if weather is expected to stay good, otherwise CLOSE| | |Dome|Unplug power to dome shutter| | |Dome|Dome short can stay "OUT" if weather is expected to remain good, otherwise "IN"| | |Dome|Dewar can stay in place during the day| | |Control room|Turn OFF remaining TV feed monitors| | |Control room|Complete and submit Trouble Report| | |Control room|Power down Xterm monitors (they do not sleep automatically)| |