===Rolf's Modified VATT Warm Shutdown Check List 2006-05-05=== Last updated: Dec 12 2011 RAJ =====2nd floor control room===== - turn off the dome fan - stow telescope (using "Stow" button in the VATT TCS/IF gui) - disable drives ("Disable drives" in the TCS "mount control" view) // **NB: only when telescope is balanced, i.e., before closing mirror cover!** - close the mirror cover ("Close M-Cover") - close the dome shutter ("Close Slit") - turn off autocollimation (VGAG-->"Secondary" menu) - turn off the mirror thermal system (TCS "thermal" view "Off") - turn off the mirror cell fans ("Cell Fans Off" in TCS "mount control") - in XEphem, disable "running" in the telescope control window and close \\ it, then exit the "Sky View" window, then at the bottom of the main // XEphem window hit "Stop", then exit XEphem altogether. - exit the VGAG window and the square TCS window; leave the TCS/IF gui \\ open if you want to keep reading UT during subsequent calibrations - turn off the guider, finder, and all-sky monitors =====2nd floor TCS/instrument room===== - turn off the power amplifiers for derotator, azimuth, elevation and \\ dome. =====2nd floor pier===== - turn off the NESLAB (almost close the valve before switching off) =====basement===== - turn off the oil system by first turning off the knob labeled #2, then \\ pushing in the mushroom button labeled #1. - turn off the pier and building fans, then turn off the light. =====dome===== - close the finder cover - unplug the finder power adapter - turn off the SBIG camera - unplug the dome power (yellow plug) - connect the grounding wire (from the mirror cell to dewar as indicated) \\ then fill the dewar - let the rubber hose thaw, then remove needle from dewar, disconnect the \\ grounding wire (dewar side first), and move LN2 tank out of the way. - (put in the stow pins in case of a full shutdown) - (put in the dome short in case of a full shutdown) - check that the West door is locked, turn off the fluorescent lights =====2nd floor control room===== - turn off the incandescent telescope flood light. - lock the doors to both balconies. - turn off all lights.