^ ^ Warm Shutdown / July 8, 2021 / P Gabor, D Brown ^ ✔✘ ^ |Control room|Turn on dome floodlight (left of the SW balcony door)| | |Control room|Turn off the main dome fan (red button on a strip to the right of the SW balcony door)| | |Control room|TCSglue main window: STOW; watch telescope move| | |Control room|MOUNT CONTROL tab: Disable drives (listen for air being released from brake)| | |Control room|MOUNT CONTROL tab: Close mirror cover (listen for sound of proper operation)| | |Control room|MOUNT CONTROL tab: Close dome shutter (slit) (listen for sound of proper operation)| | |Control room|TSCglue main window: stop dome tracking (toggling the button)| | |Control room|XEPHEM: //If applicable,// load data memory window: KILL ("X" out)| | |Control room|XEPHEM: main window, ''File'' pull-down menu: select ''Quit'' and answer in the affirmative that you wish to exit XEPHEM| | |Control room|PHD2: click the ''Connect'' icon (looks like a male USB connector) on the main task bar; click ''Disconnect'' camera and mount; exit PHD2| | |Control room|Secondary and Guidebox GUI: Secondary (top part): copy values to trouble report, turn off autocollimation, disconnect; Guidebox (bottom part): disconnect; kill the terminal in which the ''Secondary and Guidebox INDI'' is running| | |Control room|INDI: find the terminal in which INDI is running and kill it| | |Control room|THERMAL tab: radio button ''OFF''| | |Control room|CONTROL tab: cell fans ''OFF'' | | |Silo 2nd lvl|NESLAB: Simultaneously: toggle fron panel ON/OFF switch to "OFF" & slowly lower manual valve lever| | |TCS room|Toggle power switches "OFF": AZ, EL, DEROTATOR & DOME amplifiers| | |TCS room|M2 PI Controller: turn off| | |TCS room|//OPTIONAL (useful once or twice a week):// turn off VATTtel and Guider Control Box | | |Basement|STEP TWO (labeled as such): Rotate pumps switch counterclockwise to "OFF"| | |Basement|STEP ONE (labeled as such): Push in red switch, upper left corner of control box| | |Basement|Turn off building & pier fans| | |Dome|Engage stow pins (~0 on LCD readout)| | |Dome|**VATT 4k CCD Imager only:** connect camera ground wire| | |Dome|**VATT 4k CCD Imager only:** place LN2 dewar under telescope, connect hose and charge camera dewar with LN2| | |Dome|**VATT 4k CCD Imager only:** fill out camera LN2 log sheet| | |Dome|//Optional:// Power "OFF" guider camera power supply (white in-line switch). Especially in hot weather it may be better to keep it powered up, with the thermoelectric cooling running. | | |Dome|Close finder telescope objective cover| | |Dome|Turn off power supply of finder telescope camera (on top of box on South side of East fork)| | |Dome|Dome vent registers: leave OPEN if weather is expected to stay good, otherwise CLOSE| | |Dome|Unplug power to dome shutter| | |Dome|Dome short can stay "OUT" if weather is expected to remain good, otherwise "IN"| | |Dome|**VATT 4k CCD Imager only:** LN2 dewar can stay in place during the day| | |Control room|Turn OFF dome flood light (switch to the left of the SW balcony door| | |Control room|Turn OFF remaining TV feed monitors and intercom| | |Control room|**PEPSI only:** shut down VNC connection to PEPSI by going to the terminal whence it was launched and killing the process with CTRL-C; log out of //vattarchive// on both terminals| | |Control room|Complete and submit Trouble Report; print out a copy (CTRL-P) and file it| | |Control room|Power down Xterm monitors (some of them do not sleep automatically)| | |everywhere|Make sure that the building is locked before going to bed| |