=====Lightning Shutdown===== - Complete "End of Normal Night of Observing" shutdown - In Dome * Turn off all instrument electronics, including the camera shutter, and unplug two power strips and CCD power cord from orange plugs under the telescope. * On the west side, two power strips are now plugged into the two outlets. Those are what need to be unplugged for lightning shutdown on this side * If in use: shut down laptop computer, and unplug laptop from the orange UPS outlets located near the floor on the platform control console * Turn off TCS computer using the light switch * Turn off telescope power * Lower platform * Turn off main power - In Control room * On BIGAUX double click "shutdown bigpop", and click "shutdown bigpop" when prompted. You will need to enter the username "bigobs" and the Gerard password. * Manually shutdown all computers. * Gerard * BIGCCD * Bigguider * BIGAUX * Turn off printer. * Turn off Telcom server * Turn off and unplug power strip on west wall. * Unplug printer relay. * Unplug everything from orange outlets behind observer work station, as well as UPS outlets by the video finder scope monitor * Unplug computer racks (plugged into orange outlet #4 on wall below emergency stop) - In UPS Room, unplug: * The emergency stop plug (bright yellow) no longer needs to be unplugged when going into lightning shutdown. * GPS * Shutdown UPS following instructions posted on board.