====== PHD2 Guiding ====== ===== C. Johnson ===== === 3/16/2018 === === updated Oct 3, 2018 by P Gabor & C Johnson === All of the required software is currently installed on the ''vattcontrol'' server; login as vattobs. {{ :phd2:warning_about_legacy_guider_app.png?nolink |}} (*) When using VATT4k and GUFI, these motors move the two filter wheels for the science camera, the guider camera's filter wheel, the guider camera's 3-axis translation stage, and the stage carrying the center mirror and the U mirror. * **Start indiserver**: * click the indiserver icon on the desktop * (a terminal window should appear) * **Start phd2 guiding:** * click the PHD2 icon on the desktop * (the PHD2 application should appear) * **Configure phd2:** - in the ''Main tool bar'', click icon that looks like a usb male connector * (''connect equipment'' window should appear) - in ''connect equipment'' window verify the following settings: * equipment profile "vatt imagers" or "vatt spec" depending on your instrument (the imagers are 4k CCD and GUFI), - in ''connect equipment'' window, in the camera row, click on the icon that looks like a screwdriver and wrench in an "X" * (''INDI Configuration'' window should appear) - in ''INDI Configuration'' window click the ''INDI'' button near the bottom of the window * (''INDI options'' window should appear) - select the ''Apogee CCD'' tab - verify the following settings: * in the network section: * offset guider (used with imagers) ip:port : 10.0.3.14:2571; slit plate guider (used with VATTspec): 10.0.3.12:2571 - click the ''connect'' button in the ''Connection'' field * (after a few seconds, a bunch of new fields and tabs should appear) * (The message "[ERROR] Model is not supported by the INDI Apogee driver" may mean that the camera is not powered up.) - near the bottom of the window, turn on the cooler - IF YOU ARE GOING TO BE AUTOGUIDING: * click on the "VATT-GUIDE-INDI" TAB * click "Connect" * (a UT clock should appear and begin incrementing.) - exit the ''INDI options'' window - click OK in the ''INDI Configuration'' window - click ''Connect'' in the ''Connect Equipment'' window, in the camera section * (the button should now say ''Disconnect'') - IF YOU ARE GOING TO BE AUTOGUIDING: * click ''Connect'' in the ''Connect Equipment'' window, in the mount section * (the button should now say ''Disconnect'') - click ''Close'' in the ''Connect Equipment'' window - (OPTIONAL) Set up automatic frame capture: * Select the ''Global'' tab, it is part of 'advanced setup' (the brain symbol) * check ''Enable diagnostic image logging'', then * in the group ''Save Guider Images'' check ''Until this count is reached'', and * set the value (100 is the maximum). * the files are stored on the ''vattcontrol'' server * The Dark Library is located in the directory ''/home/vattobs/.phd2/''. * The directory ''/home/vattobs/PHD2/PHD2_CameraFrames...'' is automatically created for the session. * If you need to capture more than 100 images, make a renamed copy of the session directory; new //fits// files should start populating the original sesson directory. * **Move U-Mirror** - Use the Secondary App to move the Guide Camera stage so that it is on the U-Mirror. * **Start Imaging:** - in the bottom left of the PHD2 window there is a button with 2 arrows forming a circle. Click that button. - the button should gray out, the stop sign button should turn red, and images should start appearing * **Start Guiding:** - change the exposure time setting and contrast slider to find an appropriate guide star. - Click on the guide star - click on the circular icon i the tool bar that looks like a target Offset Guider Stage Note: All numbers are GUI units. The travel limits are accurate but the diagram is only an approximation. {{ :phd2:offset_guider_stage_2.gif?direct |}}