====== PHD2 Guiding ====== ===== C. Johnson ===== === 3/16/2018 === === updated Oct 3, 2018 by P Gabor & C Johnson === All of the required software is currently installed on the ''vattcontrol'' server; login as vattobs. {{ :phd2:warning_about_legacy_guider_app.png?nolink |}} (*) When using VATT4k and GUFI, these motors move the two filter wheels for the science camera, the guider camera's filter wheel, the guider camera's 3-axis translation stage, and the stage carrying the center mirror and the U mirror. * start indiserver * click the indiserver icon on the desktop * (a terminal window should appear) * start phd2 guiding * click the PHD2 icon on the desktop * (the PHD2 application should appear) * configure phd2 - in the ''Main tool bar'', click icon that looks like a usb male connector * (''connect equipment'' window should appear) - in ''connect equipment'' window verify the following settings: * equipment profile "vatt imagers" or "vatt spec" depending on your instrument (the imagers are 4k CCD and GUFI), * camera type "INDI Camera", * mount type "INDI Mount", * aux type "None" - in ''connect equipment'' window, in the camera row, click on the icon that looks like a screwdriver and wrench in an "X" * (''INDI Configuration'' window should appear) - in ''INDI Configuration'' window verify the following settings: * Hostname: localhost * port: 7600 * driver: Apogee CCD * Dual CCD: Main - click the ''INDI'' button near the bottom of the window * (''INDI options'' window should appear) - select the ''Apogee CCD'' tab - verify the following settings: * in the port section ''network'' is selected * in the network section: * subnet: 10.0.255.255 * **Note the 4K guider is currently being repaired . We are using the VATTspec guider for all guiding. In practice this means the ip:port will be 10.0.3.12:2571** * offset guider (used with imagers) ip:port : 10.0.3.14:2571; slit plate guider (used with VATTspec): 10.0.3.12:2571 - click the ''connect'' button in the ''Connection'' field * (after a few seconds, a bunch of new fields and tabs should appear) * (The message "[ERROR] Model is not supported by the INDI Apogee driver" may mean that the camera is not powered up.) - near the bottom of the window, turn on the cooler - IF YOU ARE GOING TO BE AUTOGUIDING: * click on the "INDI-VATT-GUIDE" TAB * click "Connect" * (a UT clock should appear and begin incrementing.) - exit the ''INDI options'' window - click OK in the ''INDI Configuration'' window - click ''Connect'' in the ''Connect Equipment'' window, in the camera section * (the button should now say ''Disconnect'') - IF YOU ARE GOING TO BE AUTOGUIDING: * in ''INDI Configuration'' window verify the following settings: * Hostname: localhost * port: 7600 * driver: VATT-GUIDE-INDI * Port: [empty] * exit the INDI Configuration window * click ''Connect'' in the ''Connect Equipment'' window, in the mount section * (the button should now say ''Disconnect'') - click ''Close'' in the ''Connect Equipment'' window - In the ''Main tool bar'' (it may be positioned anywhere in the window), * click the ''Advanced setup'' (brain icon) button (second from the right); a new window should appear. - Set binning to the allowed maximum of 8x8: * Select the ''Camera'' tab, * in the group ''Camera-specific properties'', set binning to 8 (pull down selector). * [Note. Ostensibly, binning can be set via ''INDI options'' as NxM where N and M may take any value you wish. This feature does not work. Binning can really be set only via "brain" button.] - IF YOU WILL NOT BE AUTOGUIDING: Disable mount guide output: * Select the ''Guiding'' tab, * in the group ''Shared parameters'' disable //mount guide output// (uncheck the box); ''Guide output DISABLED'' should appear in the lower left of the main window. This should prevent PHD2 accidentally interfering, e.g., with the PEPSI guider. - Set up automatic frame capture: * Select the ''Global'' tab, * check ''Enable diagnostic image logging'', then * in the group ''Save Guider Images'' check ''Until this count is reached'', and * set the value (100 is the maximum). * the files are stored on the ''vattcontrol'' server * The Dark Library is located in the directory ''/home/vattobs/.phd2/''. * The directory ''/home/vattobs/PHD2/PHD2_CameraFrames...'' is automatically created for the session. * If you need to capture more than 100 images, make a renamed copy of the session directory; new //fits// files should start populating the original sesson directory. * Start Imaging - in the bottom left of the PHD2 window there is a button with 2 arrows forming a circle. Click that button. - the button should gray out, the stop sign button should turn red, and images should start appearing * Start Guiding - change the exposure time setting and contrast slider to find an appropriate guide star. - Click on the guide star - click on the circular icon i the tool bar that looks like a target Offset Guider Stage Note: All numbers are GUI units. The travel limits are accurate but the diagram is only an approximation. {{ :phd2:offset_guider_stage_2.gif?direct |}}