User Tools

Site Tools


vatt:vatt_don_lightning_shutdown_checklist

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
vatt:vatt_don_lightning_shutdown_checklist [2024/06/11 17:16]
paul
vatt:vatt_don_lightning_shutdown_checklist [2024/06/11 17:34] (current)
paul
Line 6: Line 6:
 |**General rule 1**^=) Always make sure you will know how to reconnect any cables you disconnect!| | |**General rule 1**^=) Always make sure you will know how to reconnect any cables you disconnect!| |
 | | | | | | | |
-|**Prerequisite**  ^ 8-) Observatory is in “warm” shutdown. 8-) | |+|**Prerequisite**  ^ 8-) Observatory is in “warm” shutdown. 8-) | |
 |::: |Assumes Don's ''Automated Shutdown'' complete :?:, INDI server and drivers off, and all other relevant software stopped :?: |::: | |::: |Assumes Don's ''Automated Shutdown'' complete :?:, INDI server and drivers off, and all other relevant software stopped :?: |::: |
 | | | | | | | |
Line 46: Line 46:
 |Control room |It is possible that Don will display the following alarm: ''GENE AL 2, emergency stop (emergency stop is active)'' When this happens take the following action:| |  |Control room |It is possible that Don will display the following alarm: ''GENE AL 2, emergency stop (emergency stop is active)'' When this happens take the following action:| | 
 |Silo, level 2 |On the Master Control Cabinet's left door, there is a button marked ''Reset ESTOP2''. If it is flashing blue, press it. | | |Silo, level 2 |On the Master Control Cabinet's left door, there is a button marked ''Reset ESTOP2''. If it is flashing blue, press it. | |
 +|Control room |TomPack Viewer > Main Controls > Oil System > Temperature Regulation : turn the system ''ON''. Note: This system is designed to run all the time. That is why the user cannot turn it off once it is running. But, it does not come on automatically when the systems comes live after a lightning shutdown. Therefore, you should turn it on at this point. | | 
 | | | | | | | |
 |**Note 1** =)|Booting up ''vattdata'' is slow (approx. 10 mins). You can follow the process on its terminal: On the KVM (keyboard-video-mouse) console ([[vatt:miscellaneous_tips|Tips on how to use the unit.]]), highlight the entry labeled ''vattdata'' using the up/down arrow keys, and press ''Enter'' When the RISC drives are mounted and the system is fully booted, the text stops scrolling on the screen and an ASCII list of 12 options appears. This indicates that all is well and no further action is required. | | |**Note 1** =)|Booting up ''vattdata'' is slow (approx. 10 mins). You can follow the process on its terminal: On the KVM (keyboard-video-mouse) console ([[vatt:miscellaneous_tips|Tips on how to use the unit.]]), highlight the entry labeled ''vattdata'' using the up/down arrow keys, and press ''Enter'' When the RISC drives are mounted and the system is fully booted, the text stops scrolling on the screen and an ASCII list of 12 options appears. This indicates that all is well and no further action is required. | |
vatt/vatt_don_lightning_shutdown_checklist.1718151379.txt.gz · Last modified: 2024/06/11 17:16 by paul