This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision | ||
vatt:instrumentation_and_computers [2021/03/31 21:22] paul [VATT CCD Spectrograph - VATTSpec] |
vatt:instrumentation_and_computers [2024/07/05 13:27] (current) paul [Galway Ultra Fast Imager - GUFI] |
||
---|---|---|---|
Line 10: | Line 10: | ||
===== Galway Ultra Fast Imager - GUFI ===== | ===== Galway Ultra Fast Imager - GUFI ===== | ||
- | * This L3CCD system, based on an Andor iXon back-illuminated | + | * This is an Andor Marana 4.2B-11 |
- | * Field of view on VATT, 3 arcmin | + | * {{ : |
- | * On loan from NUI Galway, currently until June 2011. | + | * Array size: 2048 (W) x 2048 (H) 4.2 Megapixel |
- | * Consult Richard Boyle for technical details, and see the [[http:// | + | * Pixel size: 11 μm x 11 μm |
+ | * Array Area: 22.5 mm x 22.5 mm (31.9 mm diagonal) | ||
+ | * Field of view on VATT: 4.7 arcmin | ||
+ | * On loan from University of Galway. | ||
+ | * Consult Richard Boyle for technical details. | ||
Line 24: | Line 28: | ||
* effective back focal distance, from guide box to focal surface, is 2.000" | * effective back focal distance, from guide box to focal surface, is 2.000" | ||
* contains two filter wheels, each holding four 3.48" square filters. Adapters to accommodate 2" and 3" square filters are available. | * contains two filter wheels, each holding four 3.48" square filters. Adapters to accommodate 2" and 3" square filters are available. | ||
- | * UBVRI, uvby, Vilnius, Sloan, ECAS, and Order Blocking filters are currently provided. | + | * UBVRI, uvby, Vilnius, Sloan, ECAS, and Order Blocking |
* integrating sphere with continuum and calibration lamps. | * integrating sphere with continuum and calibration lamps. |