 ==== Basic Operation ==== ==== Basic Operation ====
 +
 +
  
 === Quick Start === === Quick Start ===
Line 31: Line 33:
   * Click the Connect button on the top right. The background should turn green and you should see information scroll by in the dialog box at the bottom.   * Click the Connect button on the top right. The background should turn green and you should see information scroll by in the dialog box at the bottom.
   * Click the Reference button. Background should turn yellow for a moment and then green or straight to green   * Click the Reference button. Background should turn yellow for a moment and then green or straight to green
-  * Click the Auto Collimate button. The background should turn green and the Focus Tip X and Tip Y should move to there nominal zero which is -1750, -40, -60 respectively. +  * Click the Auto Collimate button. The background should turn green and the FocusTip X and Tip Y should move to their nominal "zeros" which are -1750, -40, -60 respectively. 
-  * Adjust Focus Tip X and Tip Y by entering a number in the input field and pressing the return button. The number to the left of the input field should move to the number in the input field   +  * Adjust Focus Tip X and Tip Y by entering a number in the input field and pressing the return button. The number to the left of the input field should move start changing
  
 +=== End of Night ===
 +  * Click Auto Collimate to turn off auto collimation. Green Background should go away. 
 +  * Click Disconnect. Green background should go away
 +  * Exit the GUI.
  
  
Line 39: Line 45:
 If the secondary becomes unresponsive or other issues arise try these steps: If the secondary becomes unresponsive or other issues arise try these steps:
  
-  - Click disconnect on the Secondary and then click connect.  +  - Click disconnect on the Secondary and then click connect. 
-  - Click the refresh icon at the bottom of the GUI. +  - Click the refresh icon at the bottom of the GUI.
   - Exit the GUI by killing the window and re open it.   - Exit the GUI by killing the window and re open it.
   - Turn the Secondary control box off in the vatttel room weight five seconds and turn it back on.   - Turn the Secondary control box off in the vatttel room weight five seconds and turn it back on.
-  - Restart the GUI on vatt control and see if you can connect. +  - Restart the GUI on vatt control and see if you can connect.
  
  
Line 49: Line 55:
 If none of these items fix your problem: If none of these items fix your problem:
  
-Call Scott at 520 499 4860 +**Call Scott at 520 499 4860**  
 + 
  