 ====Sunnyside 2m chamber description==== ====Sunnyside 2m chamber description====
- +  * The vacuum chamber diameter84” I.D 
-  * The vacuum chamber diameter is 84” I.D +  * The vacuum chamber height12’ (13’ including hemispherical bottom).
-  * The vacuum chamber height is 12’ (13’ including hemispherical bottom).+
   * The chamber has one filament ring 71.75” diameter (center of filaments).   * The chamber has one filament ring 71.75” diameter (center of filaments).
   * The chamber wall to the center of the filaments is 6.125”.   * The chamber wall to the center of the filaments is 6.125”.
Line 23: Line 22:
   * High vacuum pressure is measured with Granville-Phillips Series 270 controllers with Bayard-Alpert Series 274 ionization gauges.   * High vacuum pressure is measured with Granville-Phillips Series 270 controllers with Bayard-Alpert Series 274 ionization gauges.
   * The deposition rate and total thickness are measured by a Maxtek TM-100 R, 6.0 MHz quartz crystal microbalance.   * The deposition rate and total thickness are measured by a Maxtek TM-100 R, 6.0 MHz quartz crystal microbalance.
 + 
 [[.:Sunnyside Chamber Lid Drawings]] [[.:Sunnyside Chamber Lid Drawings]]
  