User Tools

Site Tools


public:kitt_peak:bok_90:bok_90_inch_lightning_shutdown

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
public:kitt_peak:bok_90:bok_90_inch_lightning_shutdown [2018/09/06 14:11]
mel
public:kitt_peak:bok_90:bok_90_inch_lightning_shutdown [2019/05/22 13:58] (current)
mel
Line 1: Line 1:
-======Lightning Shutdown, Short Version: Updated 9/6/18======+======Lightning Shutdown, Short Version: Updated 2/15/19======
  
 ===Changes coming out of Downtime 2018=== ===Changes coming out of Downtime 2018===
Line 21: Line 21:
     - Turn off IIS readout and unplug     - Turn off IIS readout and unplug
     - Turn off IIS motor controller and unplug     - Turn off IIS motor controller and unplug
-    - Turn OFF and unplug 'bokccd5' CCD computer +    - Turn off and unplug 'bokccd5' CCD computer 
-  *Telescope (for other CASS users)+  *Telescope (for other CASS users [WIFIS, SPOL, SCC, PISCES])
     - Make sure everything is turned off and unplugged from orange outlets on the bottom of the telescope     - Make sure everything is turned off and unplugged from orange outlets on the bottom of the telescope
     - Make sure IIS readout and motor controller are turned off and unplugged.       - Make sure IIS readout and motor controller are turned off and unplugged.  
Line 38: Line 38:
       * Unplug dome mic if in use next to AED       * Unplug dome mic if in use next to AED
     - Observers Workstation     - Observers Workstation
-       * Shutdown AzCam program, shutdown Azcam computers (BOKCCD2 & BOKCCD4) from start menu, and shutdown AzCam Xterm+       * Shutdown AzCam program, shutdown Azcam computers (BOKCCD2 & BOKCCD4 if in use) from start menu, and shutdown AzCam Xterm
        * Shutdown programs on Bart, shutdown Bart from Start Menu, and Bart Xterm        * Shutdown programs on Bart, shutdown Bart from Start Menu, and Bart Xterm
        * Shutdown weather computer        * Shutdown weather computer
Line 144: Line 144:
      - Turn on Azcam Xterm, log into BokCCD2 if using B&C or 90Prime.  Start the Azcam program.        - Turn on Azcam Xterm, log into BokCCD2 if using B&C or 90Prime.  Start the Azcam program.  
      - Start Bart Xterm, login either as Primefocus Observer if you're using 90Prime, or Bok Observer with any other instrument using appropriate passwords.  Start programs on Bart.        - Start Bart Xterm, login either as Primefocus Observer if you're using 90Prime, or Bok Observer with any other instrument using appropriate passwords.  Start programs on Bart.  
 +     - Start weather computer by pressing button on top of the upper left edge.  Enter the password posted on the monitor.
   * At the Operators Console:   * At the Operators Console:
      - Make sure the CONSOLE UPS is plugged in and turned ON (should be done already if the above steps were followed)      - Make sure the CONSOLE UPS is plugged in and turned ON (should be done already if the above steps were followed)
public/kitt_peak/bok_90/bok_90_inch_lightning_shutdown.1536268271.txt.gz · Last modified: 2018/09/06 14:11 by mel