This shows you the differences between two versions of the page.
| Both sides previous revision Previous revision Next revision | Previous revision | ||
|
public:kitt_peak:bok_90:bok_90_inch_lightning_shutdown [2018/09/06 14:11] mel |
public:kitt_peak:bok_90:bok_90_inch_lightning_shutdown [2019/05/22 13:58] (current) mel |
||
|---|---|---|---|
| Line 1: | Line 1: | ||
| - | ======Lightning Shutdown, Short Version: Updated | + | ======Lightning Shutdown, Short Version: Updated |
| ===Changes coming out of Downtime 2018=== | ===Changes coming out of Downtime 2018=== | ||
| Line 21: | Line 21: | ||
| - Turn off IIS readout and unplug | - Turn off IIS readout and unplug | ||
| - Turn off IIS motor controller and unplug | - Turn off IIS motor controller and unplug | ||
| - | - Turn OFF and unplug ' | + | - Turn off and unplug ' |
| - | *Telescope (for other CASS users) | + | *Telescope (for other CASS users [WIFIS, SPOL, SCC, PISCES]) |
| - Make sure everything is turned off and unplugged from orange outlets on the bottom of the telescope | - Make sure everything is turned off and unplugged from orange outlets on the bottom of the telescope | ||
| - Make sure IIS readout and motor controller are turned off and unplugged. | - Make sure IIS readout and motor controller are turned off and unplugged. | ||
| Line 38: | Line 38: | ||
| * Unplug dome mic if in use next to AED | * Unplug dome mic if in use next to AED | ||
| - Observers Workstation | - Observers Workstation | ||
| - | * Shutdown AzCam program, shutdown Azcam computers (BOKCCD2 & BOKCCD4) from start menu, and shutdown AzCam Xterm | + | * Shutdown AzCam program, shutdown Azcam computers (BOKCCD2 & BOKCCD4 |
| * Shutdown programs on Bart, shutdown Bart from Start Menu, and Bart Xterm | * Shutdown programs on Bart, shutdown Bart from Start Menu, and Bart Xterm | ||
| * Shutdown weather computer | * Shutdown weather computer | ||
| Line 144: | Line 144: | ||
| - Turn on Azcam Xterm, log into BokCCD2 if using B&C or 90Prime. | - Turn on Azcam Xterm, log into BokCCD2 if using B&C or 90Prime. | ||
| - Start Bart Xterm, login either as Primefocus Observer if you're using 90Prime, or Bok Observer with any other instrument using appropriate passwords. | - Start Bart Xterm, login either as Primefocus Observer if you're using 90Prime, or Bok Observer with any other instrument using appropriate passwords. | ||
| + | - Start weather computer by pressing button on top of the upper left edge. Enter the password posted on the monitor. | ||
| * At the Operators Console: | * At the Operators Console: | ||
| - Make sure the CONSOLE UPS is plugged in and turned ON (should be done already if the above steps were followed) | - Make sure the CONSOLE UPS is plugged in and turned ON (should be done already if the above steps were followed) | ||