 +======Lightning Shutdown, Short Version: Updated 2/15/19======
 +
 +===Changes coming out of Downtime 2018===
 +  - We have an "always on" UPS now, which feeds a power strip above BokAux.  The Aux computer, the WIFI, BokPOP, and the phones are all plugged into this power strip which means these are now always left on.  You can use BokAux now to keep an eye on the weather by pulling up the weather sites bookmarked on the computer in Firefox.
 +  - BokCCD2 is now the main Azcam computer for both the B&C and 90Prime instruments.  We are going to have a spare Azcam Login machine (BokCCD4) in the future.  The username and password to get in are the same as before.  
 +  - There is no longer an UPS under the counter feeding console power.  There is a new UPS in the black computer rack labeled "Console UPS"  To shut this down you press the on/off button and select "Off Immediately" with the OK button.  This takes a while to shut off. When you turn it back on using the power button, you must use the arrow keys and OK button to choose "On Immediately" or it will not turn on.  
 +  - The weather computer is now password protected, and the password is posted on the monitor.  You turn on the weather computer by pressing the top edge of the left hand corner (it's beveled at a 45 degree angle), of the PC mounted on the wall next to the monitor.   
 +
 +
 ===== CASS (B&C, WIFIS, SCC) Lightning Shutdown ===== ===== CASS (B&C, WIFIS, SCC) Lightning Shutdown =====
  
Line 12: Line 21:
     - Turn off IIS readout and unplug     - Turn off IIS readout and unplug
     - Turn off IIS motor controller and unplug     - Turn off IIS motor controller and unplug
-  *Telescope (for other CASS users)+    - Turn off and unplug 'bokccd5' CCD computer 
 +  *Telescope (for other CASS users [WIFIS, SPOL, SCC, PISCES])
     - Make sure everything is turned off and unplugged from orange outlets on the bottom of the telescope     - Make sure everything is turned off and unplugged from orange outlets on the bottom of the telescope
     - Make sure IIS readout and motor controller are turned off and unplugged.       - Make sure IIS readout and motor controller are turned off and unplugged.  
Line 28: Line 38:
       * Unplug dome mic if in use next to AED       * Unplug dome mic if in use next to AED
     - Observers Workstation     - Observers Workstation
-       * Shutdown AzCam program, shutdown Azcam computer (BOKCCD1) from start menu, and shutdown AzCam Xterm+       * Shutdown AzCam program, shutdown Azcam computers (BOKCCD2 & BOKCCD4 if in use) from start menu, and shutdown AzCam Xterm
        * Shutdown programs on Bart, shutdown Bart from Start Menu, and Bart Xterm        * Shutdown programs on Bart, shutdown Bart from Start Menu, and Bart Xterm
        * Shutdown weather computer        * Shutdown weather computer
     -Electronics Computer Rack Area     -Electronics Computer Rack Area
-       * Using the KVM switch make sure all computers in the rack are off: +       * Using the KVM switch make sure all computers in the rack are off (**except BOKPOP**)
-         * #1 Bokccd1 B&(Should already be off) +         * #2 Bokccd2 Azcam Login (Should already be off) 
-         * #5 Bart (should already be off+         * #5 Priscilla (if in use
-         * #6 Priscilla (if in use+         * #6 Bart (should already be off
-         * #7 BokPOP +         * **#7 BokPOP (Please leave BOKPOP turned ON)**
-       Shut down Bokaux computer+
        * Turn off flat field lamp controller if in use        * Turn off flat field lamp controller if in use
        * Turn off printer        * Turn off printer
-       * Turn off (2) UPS units in bottom of the rack  +       * Turn off (3) UPS units in bottom of the rack  
-       * Note:  The CONTROL ROOM UPS also powers the Operators Console, make sure everything in it is turned off first.+       * Note:  The CONSOLE UPS powers the Operators Console, make sure everything in it is turned off first.  You will need to hit the power button, then use the arrow and OK buttons to choose "Off Immediately" or it will not shut down.  
  
  
Line 47: Line 56:
     - Unplug three plugs with red tape on your right as you enter the door down low     - Unplug three plugs with red tape on your right as you enter the door down low
     - Unplug 1 twist lock plug with red tape west wall     - Unplug 1 twist lock plug with red tape west wall
-    - Unplug GPS Ethernet cable, B&cable and power cable on west wall+    - Unplug Brandywine NTP Server'Ethernet cable, BNC cable and power cable on west wall
  
   *Second Floor Pier Room   *Second Floor Pier Room
Line 81: Line 90:
        * Shutdown weather computer        * Shutdown weather computer
     -Electronics Computer Rack Area      -Electronics Computer Rack Area 
-      * Using the KVM switch make sure all computers in the rack are off +      * Using the KVM switch make sure all computers in the rack are off **except BokPOP** 
-        * #2 Bokccd2 90Prime (should already be off) +        * #2 Bokccd2 Azcam Login 
-        * #4 Bokccd4 90prime spare +        * #4 Bokccd4 Spare Azcam Login  
-        * #Bart (should already be off) +        * #5 Priscilla (if in use) 
-        * #7 BokPOP +        * #6 Bart (should already be off) 
-      Shut down bokaux computer+        * #7 BokPOP **(should stay ON)**
       * Turn off flat field lamp controller if in use       * Turn off flat field lamp controller if in use
       * Turn off printer       * Turn off printer
-      * Turn off (2) UPS units in bottom of the rack +      * Turn off (3) UPS units in bottom of the rack 
-      * * Note:  The CONTROL ROOM UPS also powers the Operators Console, make sure everything in it is turned off first.+      * * Note:  The CONSOLE UPS powers the Operators Console, make sure everything in it is turned off first.  You will need to hit the power button, then use the arrow and OK buttons to choose "Off Immediately" or it will not shut down.  
  
   *Warm Room Cable Closet   *Warm Room Cable Closet
     - Unplug three plugs with red tape on your right as you enter the door down low     - Unplug three plugs with red tape on your right as you enter the door down low
     - Unplug 1 twist lock plug with red tape west wall     - Unplug 1 twist lock plug with red tape west wall
-    - Unplug GPS Ethernet cable, B&cable and power cable on west wall+    - Plug in Brandywine NTP Server'Ethernet cable, BNC cableand power cable on west wall
  
   *Second Floor Pier Room   *Second Floor Pier Room
Line 117: Line 126:
     -Plug in three plugs with red tape on your right as you enter the door down low     -Plug in three plugs with red tape on your right as you enter the door down low
     -Plug in 1 twist lock plug with red tape west wall     -Plug in 1 twist lock plug with red tape west wall
-    -Plug in GPS Ethernet cable, B&cable and power cable on west wall+    -Plug in Brandywine NTP Server'Ethernet cable, BNC cable and power cable on west wall
  
   *Electronics Computer Rack Area   *Electronics Computer Rack Area
-    - Turn on (2) UPS units in bottom of the rack +    - Turn on (3) UPS units in bottom of the rack.  On the new Console UPS: You will need to hit the power button, then use the arrow and OK buttons to choose "On Immediately" or it will not turn on.   
-    - Turn on Bokpop+ 
 +    - Turn on Bokpop (it should already be ON)
     - Turn on Bart     - Turn on Bart
-    - Turn on BokAux+    - Turn on BokAux (should already be on)
     - Turn on printer     - Turn on printer
     - **90Prime users**     - **90Prime users**
-      -Turn on BokCCD2 +      Turn on BokCCD2 
-      -Turn on two rotary switches labeled "90Prime CCD" and "90Prime System" +      Turn on two rotary switches labeled "90Prime CCD" and "90Prime System" 
     - **B&C users**     - **B&C users**
-      Turn on BokCCD1+      Turn on BokCCD2
  
   *Observers Work Station   *Observers Work Station
-     - Turn on Azcam Xterm, log into BokCCD1 if using B&C, and BokCCD2 if using 90Prime.  Start the Azcam program.  +     - Turn on Azcam Xterm, log into BokCCD2 if using B&or 90Prime.  Start the Azcam program.  
      - Start Bart Xterm, login either as Primefocus Observer if you're using 90Prime, or Bok Observer with any other instrument using appropriate passwords.  Start programs on Bart.        - Start Bart Xterm, login either as Primefocus Observer if you're using 90Prime, or Bok Observer with any other instrument using appropriate passwords.  Start programs on Bart.  
 +     - Start weather computer by pressing button on top of the upper left edge.  Enter the password posted on the monitor.
   * At the Operators Console:   * At the Operators Console:
-     - Make sure the CONTROL ROOM UPS is plugged in and turned ON (should be done already if the above steps were followed)+     - Make sure the CONSOLE UPS is plugged in and turned ON (should be done already if the above steps were followed)
      - Pull out emergency stop button on console      - Pull out emergency stop button on console
      - Turn on TCS computer      - Turn on TCS computer
Line 156: Line 167:
      - Plug in IIS readout and turn on      - Plug in IIS readout and turn on
      - Plug in IIS motor controller and turn on      - Plug in IIS motor controller and turn on
 +     - Plug in and turn ON "bokccd5" CCD control computer
      
      