This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision | ||
public:catalinas:lemmon:schulman_32:startup_procedure [2022/09/14 14:33] tdeyoe [Check RA Encoder Tape] |
public:catalinas:lemmon:schulman_32:startup_procedure [2022/09/23 11:39] (current) tdeyoe |
||
---|---|---|---|
Line 1: | Line 1: | ||
- | ====== | + | ====== |
Updated 8/4/2022 - Travis Deyoe | Updated 8/4/2022 - Travis Deyoe | ||
Line 33: | Line 33: | ||
If anything is observed, use a microfiber cloth or TEX wipe to wipe it away. You can use 99% isopropyl alcohol if necessary. Note that you should only wipe along the narrow width NOT along the circumference (or length) of the tape. | If anything is observed, use a microfiber cloth or TEX wipe to wipe it away. You can use 99% isopropyl alcohol if necessary. Note that you should only wipe along the narrow width NOT along the circumference (or length) of the tape. | ||
- | ===== Powering | + | ===== Powering |
- | Now that you have inspected the telescope for safety it is now time to start turning things on. | + | Now that you have inspected the telescope for safety, it is now time to start turning things on. |
==== Power On UPS's ==== | ==== Power On UPS's ==== | ||
- | First plug in the Big and Small UPS's to the left of the desk. The BIG UPS should be twisted clockwise after insertion in order to secure it in the socket. The Big UPS powers the larger controller box on the wall above it while the Small UPS powers basically everything else. | + | First plug in the big and small UPS's to the left of the desk. The big UPS should be twisted clockwise after insertion in order to secure it in the socket. The big UPS powers the larger controller box on the wall above it, while the small UPS powers basically everything else. |
{{public: | {{public: | ||
{{public: | {{public: | ||
- | Next you must turn on both UPS's. Press and hold the corresponding " | + | Next you must turn on both UPS's. Press and hold the corresponding " |
{{: | {{: | ||
{{: | {{: | ||
- | Both UPSs will immediately supply power to their output plugs so no further button pressing is necessary. | + | Both UPS' |
- | ==== Power On Controller and Desktop | + | ==== Power On Controller and Desktop |
- | The big gray box on the wall is the Controller. Turn it on by turning the large red switch on the bottom left of the Controller box to the right (clockwise). Assuming the UPS was powered on in the last step Fans and other noises will be heard as the system comes on. | + | The big gray box on the wall is the Controller. Turn it on by turning the large red switch on the bottom left of the Controller box to the right (clockwise). Assuming the UPS was powered on in the last step, fans and other noises will be heard as the system comes on. |
{{: | {{: | ||
- | Now is also when you should turn on the Desktop | + | Now is also when you should turn on the desktop |
==== Power on TIM Unit ==== | ==== Power on TIM Unit ==== | ||
Line 61: | Line 61: | ||
==== Check Controller Ethernet Cable ==== | ==== Check Controller Ethernet Cable ==== | ||
- | While the Controller and Desktop | + | While the Controller and desktop computer |
{{: | {{: | ||
===== Desktop Tasks ===== | ===== Desktop Tasks ===== | ||
- | Procced back to the desktop computer which should be fully powered on. Login to the computer (standard SkyCenter password). The next few task will all be done on this computer. | + | Procced back to the desktop computer, which should be fully powered on. Log in to the computer (standard SkyCenter password). The next few tasks will all be done on this computer. |
==== Open Mirror Covers==== | ==== Open Mirror Covers==== | ||
Line 73: | Line 73: | ||
{{: | {{: | ||
- | Connect to the TIM unit and navigate to the " | + | Connect to the TIM unit (by clicking the connect button) |
{{: | {{: | ||
- | Open the Mirror Covers: | + | Open the mirror covers by clicking the " |
{{: | {{: | ||
- | If the mirror covers aren't opening correctly or the current stays high (over 1000milliamps) then there is a problem. Abort the opening (or closing) | + | If the mirror covers aren't opening correctly or the current stays high (over 1000 milliamps) then there is a problem. Abort the opening (or closing). You attempt to open them again but if the problem persists addition help is needed (AKA call Travis or ask Mountain Ops if they are still around). |
==== Remotely connect to MIC and PubSub ==== | ==== Remotely connect to MIC and PubSub ==== | ||
- | Launch [[public: | + | Launch [[public: |
{{: | {{: | ||
- | ==== Verify MIC and PubSub | + | ==== Verify MIC and PubSub |
- | **NOTE: At this time PubSub is dumb and will display a " | + | **NOTE: At this time PubSub is dumb and will display a " |
- | Make it so you can view the top right of both screens next to each other and confirm that the two computers | + | Make it so you can view the top right of both screens next to each other and confirm that the two computer |
- | ==== Launch Pubsub software | + | ==== Start PubSub Software |
- | Initially the desktop will be blank (black). Start PubSub processes by pressing the tool utility icon at the top of desktop. It is circled in the image below: | + | Initially the desktop will be blank (black). Start the PubSub processes by pressing the tool utility icon at the top of the PubSub |
{{: | {{: | ||
Line 104: | Line 104: | ||
{{: | {{: | ||
- | The small icons to the right of processes | + | The small icons to the left of each folder icon can be pressed to expand them and reveal the list as shown. Once the " |
- | From Pubsubs Desktop | + | From PubSub' |
* Main-Container | * Main-Container | ||
Line 113: | Line 113: | ||
* jTCS_0m8a_doma_tus | * jTCS_0m8a_doma_tus | ||
* Instruments-xx01_0m8a_doma | * Instruments-xx01_0m8a_doma | ||
- | * (RPC_Gateway) <--- only shows once connected (via [[startup_procedure# | + | * (RPC_Gateway) <--- only shows once connected (via [[startup_procedure# |
==== Access the LCOGT (PubSub) GUI ==== | ==== Access the LCOGT (PubSub) GUI ==== | ||
- | Now that the system is up and running with drives, servos, and PubSub- access the LCOGT GUI: | + | Now that the system is up and running with drives, servos, and PubSub, access the LCOGT GUI by following the steps below. |
Open [[public: | Open [[public: | ||
Line 123: | Line 123: | ||
{{: | {{: | ||
- | The Username is unused so leave it as is or write something funny for the next operator to see. //default// **is** required for the Config File field. Once those are confirmed click OK. | + | The Username is unused so leave it as is or write something funny for the next operator to see. However, |
- | PubSub will now take a long time to load. Go read a book (I recommend [[https:// | + | PubSub will now take a long time to load. Go read a book (I recommend [[https:// |
{{: | {{: | ||
- | Take note of the colors | + | Take note of the colors. You should mostly see grays (items that just aren't used in our setup) or greens. There may be a yellow or two, but if there is any red there may be an issue. If see red and suspect an issue call Travis. |
==== Homing the Telescope ==== | ==== Homing the Telescope ==== | ||
Line 135: | Line 135: | ||
The telescope must be homed before it can be operated. | The telescope must be homed before it can be operated. | ||
- | When PubSub loads it should already be on the //Axes// tab. If not click on it. Note that the axes are **Unhomed**. | + | When PubSub loads it should already be on the //Axes// tab. If not, click on it. |
{{: | {{: | ||
- | Press the large //HOME// button (circled below) to move both axes simultaneously to the home position. See [[public: | + | Press the large //HOME// button (circled below) |
{{: | {{: | ||
- | Once homed successfully the state field will briefly go to " | + | Once homed successfully the state field will briefly go to " |
{{: | {{: | ||
- | Now go to the //Source// tab and move the telescope out of the limits to a valid sky position. If the telescope is not going to be used immediately typically the telescope is sent to the [[public: | + | Now go to the //Source// tab and move the telescope out of the limits to a valid sky position. If the telescope is not going to be used immediately, typically the telescope is sent to the [[public: |
{{: | {{: | ||
- | Please see the Using the [[public: | + | Please see the [[public: |
===== Normal Startup Operations ===== | ===== Normal Startup Operations ===== | ||
- | You have now successfully pulled the Schulman telescope out of Lightning Shutdown! Congrats. It is now time to start your normal program procedures to get everything ready for a SkyNight | + | You have now successfully pulled the Schulman telescope out of Lightning Shutdown! Congrats. It is now time to start your normal program procedures to get everything ready for a SkyNights |