public:catalinas:lemmon:schulman_32:shutdown_procedure [2022/08/24 12:55]
tdeyoe [Main Computer and UPS's]
public:catalinas:lemmon:schulman_32:shutdown_procedure [2022/09/23 11:39] (current)
tdeyoe
Line 1: Line 1:
-====== Schulman Telescope Shutdown Procedure ======+====== DO NOT USE THIS PROCEDURE ======
  
 The steps to shutdown the telescope are somewhat the reverse of the [[schulman_telescope_startup_procedure|Startup]] process- but greatly simplified. Knowledge of the Startup process as well as [[public:catalinas:lemmon:schulman_32:using_the_lcogt_gui_and_moving_the_telescope|using the LCOGT GUI and moving the telescope]] are assumed in the steps below. The steps to shutdown the telescope are somewhat the reverse of the [[schulman_telescope_startup_procedure|Startup]] process- but greatly simplified. Knowledge of the Startup process as well as [[public:catalinas:lemmon:schulman_32:using_the_lcogt_gui_and_moving_the_telescope|using the LCOGT GUI and moving the telescope]] are assumed in the steps below.
  
  ==== Telescope and Dome ====  ==== Telescope and Dome ====
-  
  
   - Close the telescope Mirror Covers.   - Close the telescope Mirror Covers.
   - Close observatory Dome (if not already closed).   - Close observatory Dome (if not already closed).
   - Park the telescope (or move it to the park position and turn the tracking off). Make certain telescope is not tracking.    - Park the telescope (or move it to the park position and turn the tracking off). Make certain telescope is not tracking. 
-  - Make sure to leave the telescope in a balanced state. This means either with the camera on or Eyepiece and weights.+  - Make sure to leave the telescope in a balanced state. This means either with the camera on or the Eyepiece and weights on.
   - Rotate Dome (any method) to chosen safe position. Park position is currently at 59 degrees [[public:catalinas:lemmon:schulman_32:review_of_astronomical_coordinates|Azimuth]].    - Rotate Dome (any method) to chosen safe position. Park position is currently at 59 degrees [[public:catalinas:lemmon:schulman_32:review_of_astronomical_coordinates|Azimuth]]. 
   - Press the red button on the {{:maxdome_controller_box.jpg?linkonly|dome controller box}} to cut power to it.    - Press the red button on the {{:maxdome_controller_box.jpg?linkonly|dome controller box}} to cut power to it. 
  
-==== Main Computer ====+==== Main Computer Software ====
  
   - On the main observatory computer {{:acp_connect.jpg?linkonly|disconnect the telescope via ACP}} (if connected) and TIM unit.   - On the main observatory computer {{:acp_connect.jpg?linkonly|disconnect the telescope via ACP}} (if connected) and TIM unit.
-  - Close any running software on the desktop. (Though do not turn it off yet)+  - Close any running software on the desktop. (Though do not turn it off the computer just yet)
  
  
Line 31: Line 30:
   - Turn the {{:telescope_controller_switch.jpg?linkonly|red controller switch}} to "Off"   - Turn the {{:telescope_controller_switch.jpg?linkonly|red controller switch}} to "Off"
  
-==== Main Computer and UPS'====+==== Main Computer Shutdown====
  
 Now you can turn off the Main Computer via whatever method. Make sure it's off (and not installing updates) before proceeding. Now you can turn off the Main Computer via whatever method. Make sure it's off (and not installing updates) before proceeding.
  
-Turn off the Large UPS (for telescope controller) by pressing the "power" button. The screen indicates the instructions. Unplug the Large UPS from the wall.+==== UPS Shutdown ====
  
-{{:public:catalinas:lemmon:schulman_32:power_big_ups_unplug.gif?direct|}}+Turn off the Large UPS by pressing the "power" button. Turn off small UPS, this requires pressing and holding for a moment.
  
-Turn off small UPS (for computer and remote power outlets)Unplug from the wall.+{{:public:catalinas:lemmon:schulman_32:power_big_ups_off.gif?direct|}} 
 +{{:public:catalinas:lemmon:schulman_32:power_ups_off.gif?direct|}}
  
 +Unplug both UPS's from the wall now that they are off.
 +
 +{{:public:catalinas:lemmon:schulman_32:power_big_ups_unplug.gif?direct|}}
 {{:public:catalinas:lemmon:schulman_32:power_ups_unplug.gif?direct|}} {{:public:catalinas:lemmon:schulman_32:power_ups_unplug.gif?direct|}}
  
-In Warm room unplug the CAT5 cables that give service to Controller. This is to protect it from any lightning travelling through the Ethernet cable (RIP Phillips in 2019).+In Warm room unplug the ethernet cable that give service to Controller. This is to protect it from any lightning travelling through the ethernet cable (RIP Phillips in 2019). 
 + 
 +==== It's a Tarp! ====
  
 Consider covering the Telescope and main computer desk with tarps. The desk should be quite easy but the telescope can be challenging. If you do not have a helper or are simply unable to do so make sure to inform mountain operations. Consider covering the Telescope and main computer desk with tarps. The desk should be quite easy but the telescope can be challenging. If you do not have a helper or are simply unable to do so make sure to inform mountain operations.
  
  