 ====== Schulman Telescope Shutdown Procedure ====== ====== Schulman Telescope Shutdown Procedure ======
  
-The steps to shutdown the telescope are somewhat the reverse of the [[schulman_telescope_startup_procedure|Startup]] process- but greatly simplified. Knowledge of the Startup process as well as [[using_the_lcogt_gui_and_moving_the_telescope|using the LCOGT GUI and moving the telescope]] are assumed in the steps below.+The steps to shutdown the telescope are somewhat the reverse of the [[schulman_telescope_startup_procedure|Startup]] process- but greatly simplified. Knowledge of the Startup process as well as [[:using_the_lcogt_gui_and_moving_the_telescope|using the LCOGT GUI and moving the telescope]] are assumed in the steps below.
  
-The final state of the shutdown in terms of electrical isolation (lightning shutdown) and protection from the elements (covering the telescope with plastic, rotating the dome to minimize weather effects of rain and snow etc...) are not covered here. Please confer with mountain operations staff and cognizant observers and operators for more information. +The final state of the shutdown in terms of electrical isolation (lightning shutdown) and protection from the elements (covering the telescope with plastic, rotating the dome to minimize weather effects of rain and snow etc...) are not covered in totality here. Please confer with mountain operations staff and cognizant observers and operators for more information. 
  
  ==== Telescope and Dome ====  ==== Telescope and Dome ====
Line 12: Line 12:
   - Park the telescope (or move it to the park position and turn the tracking off). Make certain telescope is not tracking.    - Park the telescope (or move it to the park position and turn the tracking off). Make certain telescope is not tracking. 
   - Remove instrumentation- or if left in place, cover the primary mirror baffle tube with baffle cover. It is a good idea to leave the telescope in a balanced state.   - Remove instrumentation- or if left in place, cover the primary mirror baffle tube with baffle cover. It is a good idea to leave the telescope in a balanced state.
-  - Rotate Dome (any method) to chosen safe position. Park position is currently at 59 degrees [[review_of_astronomical_coordinates|Azimuth]]. +  - Rotate Dome (any method) to chosen safe position. Park position is currently at 59 degrees [[:review_of_astronomical_coordinates|Azimuth]]. 
  
 === Disconnect/Disable Devices (Software)=== === Disconnect/Disable Devices (Software)===
Line 19: Line 19:
   - Physically turn off the {{:tim_unit.jpg?linkonly|TIM unit}} at its rocker toggle switch.    - Physically turn off the {{:tim_unit.jpg?linkonly|TIM unit}} at its rocker toggle switch. 
   - Press the red button on the {{:maxdome_controller_box.jpg?linkonly|dome controller box}} to cut power to it.    - Press the red button on the {{:maxdome_controller_box.jpg?linkonly|dome controller box}} to cut power to it. 
-  - Close open software on the desktop. +  - Close any running software on the desktop. 
  
 ==== Controller Shutdown ==== ==== Controller Shutdown ====
Line 34: Line 34:
   - Turn the {{:telescope_controller_switch.jpg?linkonly|red controller switch}} to "Off"   - Turn the {{:telescope_controller_switch.jpg?linkonly|red controller switch}} to "Off"
  
-=== Main Computer and UPS's ===+==== Main Computer and UPS'====
  
-  - Turn off the Large UPS (for telescope controller) by pressing the "power" button. The screen indicated the instructions. +  - Turn off the Large UPS (for telescope controller) by pressing the "power" button. The screen indicates the instructions. 
   - Unplug the Large UPS from the wall.    - Unplug the Large UPS from the wall. 
   - Shutdown main observatory computer.    - Shutdown main observatory computer. 