- | =====Telescope Shutdown check List===== | + | =====End of Normal Night of Observing Checklist===== |
- | * Turn Off tracking and any bias rates that are enabled. | + | * Turn off autoguiding on bigguider (if guiding was enabled) |
- | * Stow the telescope. | + | * Home the autoguider pickoff mirror in the gerard fw gui |
- | * Stow the Dome by aligning arrows on east wall. | + | * Stow the telescope |
- | * Disable the telescope. | + | * Zero out any bias rates that are enabled. |
- | * Close mirror covers on telescope and any finderscopes | + | * Stow the dome (in XEphem |
- | * Close dome shutter. | + | * Disable the telescope, dome and focus (in XEphem Telemetry module) |
- | * Raise the lower windscreen until it's fully extended. | + | * Close mirror covers on telescope |
- | * Lower the upper windscreen until it overlaps | + | * Close dome shutter |
+ | * Raise the lower windscreen | ||
+ | * Lower the upper windscreen until it stops, overlapping | ||
* Lower the observing platform all the way down | * Lower the observing platform all the way down | ||
* Fill the dewar if needed. | * Fill the dewar if needed. | ||
- | * Bolt catwalk door. | + | * Close and bolt catwalk door. |
+ | * Verify flat field lamps are turned off. | ||
+ | * Turn off dome lights unless dome humidity is above 90%. | ||
+ | * Close the door at the top of the stairs. | ||
* Fill out and send trouble report. | * Fill out and send trouble report. | ||
- | * Check Weather forecast for the next day. If ANY chance of thunderstorms/ | + | * Check NWS Mount Bigelow |
- | * Make sure stove/oven are off and fridge is closed. | + | * Make sure stove/oven are off and fridge is fully closed. |
- | * Make sure recliner in control room is not directly in front of the heater. | + | * Wash all your dishes/ |
- | * In the winter make sure heater is on and set to 3.5. | + | * Make sure recliner in control room is not directly in front of the heater |
- | * Turn off all lights. | + | * In the winter, make sure heater is on and set to 3.5. |
+ | * Turn off all control room, restroom and hallway | ||
+ | * Make sure control room and restroom doors are closed. | ||
* Make sure front door is locked. | * Make sure front door is locked. | ||
- | * Set dome alarm. | + | * Set dome alarm and verify it is beeping before leaving. |
- | * Double check front door is locked after walking out. | + | * Double check front door is locked after walking out. |
+ | * Look up at the dome slit to verify the dome shutter really is closed. | ||
M4K Users | M4K Users | ||
- | * If not putting the telescope in lightning shutdown, please leave the Azcam program up and running! Shutting | + | * If not putting the telescope in lightning shutdown, please leave the AZcam program up and running! Shutting |