- | ^ ^ Warm Shutdown / Jan 27, 2018 / P Gabor ^ ✔✘ ^ | + | ====== PlayGround ====== |
- | |Control room|Turn on dome floodlight (left of the SW balcony door)| | | + | |
- | |Control room|Turn off the main dome fan (red button on a strip to the right of the SW balcony door)| | | + | |
- | |Control room|TCSglue main window: STOW; watch telescope move| | | + | |
- | |Control room|MOUNT CONTROL tab: Disable drives (listen for air being released from brake)| | | + | |
- | |Control room|MOUNT CONTROL tab: Close mirror cover (listen for sound of proper operation)| | | + | |
- | |Control room|MOUNT CONTROL tab: Close dome shutter (slit) (listen for sound of proper operation)| | | + | |
- | |Control room|TSCglue main window: stop dome tracking (toggling the button)| | | + | |
- | |Control room|XEPHEM: | + | |
- | |Control room|XEPHEM: | + | |
- | |Control room|Quit Xephem (or exit)| | | + | |
- | |Control room|Warning box/button: dismiss| | | + | |
- | |Control room|VATT Guider APP: " | + | |
- | |Control room|Kill VATT Guider APP| | | + | |
- | |Control room|[[vatt: | + | |
- | |Control room|THERMAL tab: radio button " | + | |
- | |Silo 2nd lvl|NESLAB: Simultaneously: | + | |
- | |Control room|MOUNT CONTROL tab: Turn cell fans " | + | |
- | |TCS room|Toggle power switches " | + | |
- | |TCS room|M2 PI Controller: turn off| | | + | |
- | |Basement|Turn off building & pier fans| | | + | |
- | |Basement|STEP TWO (labeled as such): Rotate pumps switch counterclockwise to " | + | |
- | |Basement|STEP ONE (labeled as such): Push in red switch, upper left corner of control box| | | + | |
- | |Dome|Engage stow pins| | | + | |
- | |Dome|Connect camera ground wire| | | + | |
- | |Dome|Place camera fill dewar under telescope, connect hose and charge dewar with LN2| | | + | |
- | |Dome|Fill out camera LN2 log sheet| | | + | |
- | |Dome|Power " | + | |
- | |Dome|Close finder telescope objective cover| | | + | |
- | |Dome|Turn off power supply of finder telescope camera (on top of box on South side of East fork)| | | + | |
- | |Dome|Dome vent registers: leave OPEN if weather is expected to stay good, otherwise CLOSE| | | + | |
- | |Dome|Unplug power to dome shutter| | | + | |
- | |Dome|Dome short can stay " | + | |
- | |Dome|Dewar can stay in place during the day| | | + | |
- | |Control room|Turn OFF remaining TV feed monitors| | | + | |
- | |Control room|Complete and submit Trouble Report| | | + | |
- | |Control room|Power down Xterm monitors (they do not sleep automatically)| | | + | |