 =========Operating the Exhaust fan========= =========Operating the Exhaust fan=========
 If the humidity inside the dome is high enough to prevent you from opening, but the humidity outside the dome is lower than 90%, you can turn on the exhaust fan to dry out the dome before you observe.   If the humidity inside the dome is high enough to prevent you from opening, but the humidity outside the dome is lower than 90%, you can turn on the exhaust fan to dry out the dome before you observe.  
 +
 +To do that, make sure it's safe for you to open the dome (slit pointed so if the sun is still up, no direct sunlight will get on the telescope; not raining, wind speeds within bounds).  
 +
 +Raise the platform so you have about a foot gap between the bottom of it and the surrounding floor.  
 +
 +In the control room next to the emergency stop button, there is a light switch labeled exhaust fan which can now be turned on.
 +
 +Mirror covers should be closed, and telescope should be disabled.
  
  