Line 68: Line 68:
    - Turn off all dome lights    - Turn off all dome lights
    - Close door at top of stairs    - Close door at top of stairs
 +   - Record the weather conditions at the time of opening (windspeed, direction, humidity, temperature, time)
                      
 =====Starting TCSng===== =====Starting TCSng=====
Line 140: Line 141:
     * Open ds9     * Open ds9
     * Open IRAF     * Open IRAF
-    * Start watcher+    * While not necessary to run the M4K, many observers use Betsy Green's postprocessing script "watcher" If you want to use it, here's a [[link to the instructions.]]
   - On BigCCD1   - On BigCCD1
     * Start the Azcam program from the desktop icon     * Start the Azcam program from the desktop icon
Line 221: Line 222:
   - Stow the wind screens   - Stow the wind screens
   - Fill the dewar    - Fill the dewar 
-  - Complete the trouble reports+  - Complete the trouble reports, the more detail you provide to the day crew the better! 
 +  - When you leave the building for the night, set the alarm and make sure the front door is locked
  
 =====Lightning Shutdown===== =====Lightning Shutdown=====
Line 250: Line 252:
     * Emergency Stop Power 110 VAC     * Emergency Stop Power 110 VAC
     *Shutdown UPS following instructions posted on board.     *Shutdown UPS following instructions posted on board.
 +
 +=========Operating the Exhaust fan=========
 +If the humidity inside the dome is high enough to prevent you from opening, but the humidity outside the dome is lower than 90%, you can turn on the exhaust fan to dry out the dome before you observe.  
 +
 +To do that, make sure it's safe for you to open the dome (slit pointed so if the sun is still up, no direct sunlight will get on the telescope; not raining, wind speeds within bounds).  
 +
 +Raise the platform so you have about a foot gap between the bottom of it and the surrounding floor.  
 +
 +In the control room next to the emergency stop button, there is a light switch labeled exhaust fan which can now be turned on.
 +
 +Mirror covers should be closed, and telescope should be disabled.
 +
  
 =========How to recover from Telcom issues========= =========How to recover from Telcom issues=========
kuiper/tcsng_operators_notes.1512152836.txt.gz · Last modified: 2017/12/01 11:27 by mel