   - Complete "End of Normal Night of Observing" shutdown   - Complete "End of Normal Night of Observing" shutdown
   - In Dome   - In Dome
-    * Turn off all instrument electronics, including the camera shutter, and unplug from orange outlets under scope (Four Cables) +    * Turn off all instrument electronics, including the camera shutter, and unplug two power strips and CCD power cord from orange plugs under the telescope.  
-    * If in use: shut down laptop computer, and unplug laptop and monitor from the orange UPS outlets located near the floor on the platform control console.+    * On the west side, two power strips are now plugged into the two outlets.  Those are what need to be unplugged for lightning shutdown on this side  
 +    * If in use: shut down laptop computer, and unplug laptop from the orange UPS outlets located near the floor on the platform control console 
 +    * The focus is no longer operating off the orange extension cord that plugged into the powerstrip on the south end of the scope, it’s hardwired in, so you don’t have to worry about it
     * Turn off TCS computer using the light switch     * Turn off TCS computer using the light switch
     * Turn off telescope power     * Turn off telescope power
Line 10: Line 12:
     * Turn off main power     * Turn off main power
   - In Control room   - In Control room
-    * On BIGAUX double click "shutdown bigpop", and click shutdown bigpop when prompted+    * On BIGAUX double click "shutdown bigpop", and click shutdown bigpop when prompted.  You will need to enter the username "bigobs" and the Gerard password.  
     * Manually shutdown all computers.      * Manually shutdown all computers. 
       * Gerard       * Gerard
Line 23: Line 25:
     * Unplug computer racks (plugged into orange outlet #4 on wall below emergency stop)     * Unplug computer racks (plugged into orange outlet #4 on wall below emergency stop)
   - In UPS Room, unplug:   - In UPS Room, unplug:
 +    * The emergency stop plug (bright yellow) no longer needs to be unplugged when going into lightning shutdown.
     * GPS     * GPS
-    * Emergency Stop Power 110 VAC +    * Shutdown UPS following instructions posted on board.
-    *Shutdown UPS following instructions posted on board.+