-[[21_inch:ray_white_21_inch_telescope|]]=====Telescope Control System GUI for the Ray E White Telescope.===== +===Starting TCSng=== 
- +  -Xephem 
-The Graphical User Interface (GUI) for the Ray E. White Telescope is located on the desktop of the computers in the domeThe Telescope Control computer should be running before you start the GUI program other wise the program will hangTo open the program simply double click on the icon labeled TCS GUI 03-24-2008. If everything is working correctly you should get a window that looks like this+     *Click “RT” button under looping if Xephem is not updating the time. 
- +     *Click “View” and Select “Sky View”. 
-{{wiki:finderscope-processed.jpg?500x250}} +  -In the “Sky View” window click on the “telescope” tab and select “INDI Panel” 
- +  -In the “INDI Panel” window that opens connect to the following module
-====Finder Scope Access position==== +    -Expand “TCS-NG-INDI” 
- +        *Telemetry → Connection → On 
-Generally the first function you use on the telescope is the Finder Scope Action choice in the service menu. To access this menu+  -Click “Enable” (red light next to “TCS-NG-INDI” turns green) 
-  - click on the service tab at the top +===Stopping the Telescope=== 
-  - click on the Finder Scope Access item (will be highlighted after clicking+==Using "cancel in XEphem":== 
-  - click on the Go To button located below the reload button+  -In the “Indi Panel” window  
- +    -TCS Module 
-The telescope should slew towards the northern wall so you can access the finder scope cover. +        *Telemetry → Actions → Cancel 
- +==Using "SafeTelescope" Buttons:== 
- +  -Enable/Disable and Cancel 
-====General Use==== +===Moving the Telescope=== 
- + *YOU MUST LOOK AND MAKE SURE IT IS CLEAR TO MOVE THE SCOPE (ladders out of the way,etc)
-Generallyyou will be using the GOTO tab to slew to an objectThe GOTO tab looks like this+ *Telescope must be enabled. 
- +==Ways to move:== 
-{{wiki:goto-processed.jpg?500x250}} +  -With the Sky View window 
- +    -Right click on the desired object
-There are a few ways to slew to and track an object in the night sky.  +    -Click Telescope GOTO 
- +        *The Coordinates should populate in the NEXT section of TCS telemetry 
-===Enter RA and Dec coordinates=== +    -Under “Actions” Click “Go Next”  
- +        *Watch the telescope move and make sure to move the dome! 
-To enter RA and Dec coordinates manually, make sure you are in the GOTO tab. Enter the coordinates of your object and click the Set Next buttonThe object's coordinates are now in the buffer. Click the Go Next button to slew to these coordinates +  -Equatorial Coordinates  
-     +    -In Indi control Panel: 
-===Find the object in a catalog=== +       -Under TCS-NG-INDI 
- +         -GOTO Functions 
-To slew to an object in the catalog you must be in the GOTO windowClick on the Open Catalog button in the center of the window. You will be given a list of catalog. Double click on the catalog you would likeThe objects in the catalog will be listed in the catalog box at the bottom half of the windowAll objects below the horizon are highlighted in red. Click on the object you are interested in and click the Set Next button and then Go Next buttons.  +         -Enter Desired RADec and Epoch 
- +         -Click “set” or hit the enter key 
-====Initializing the Telescope on a Bright Star==== +         -Then under “Actions” “hit Go Next” 
- +       *Watch the telescope move and make sure to move the dome! 
-In order to verify the telescope knows where it is in the sky slew to a bright star using the GOTO window. Make sure you use the Set Next button in order to put the coordinates into the bufferUse the [[ray_white_21_inch_telescope#using_dome_remote_paddle:paddle controls]] to put that object in the center of the field of view of the telescopeReturn to the GUI application and click on the Service tab. In the service tab click the Init Next Button at the bottom of the screen. +       *When moving with the Sky View Window or Entering Equatorial coordinates, the telescope will start tracking automatically. 
- +       *Remember the telescope moves much faster than the dome, and you need to watch to make sure telescope does not hit the staircases or platform attached to the dome. 
- +  -Alt/Az coordinates
-====List of Popular Stars for observing==== +    -In Indi Control Panel: 
- +      -Under TCS-NG-INDI 
-^Proper Name ^FK5 ^SAO ^Greek Letter ^Constellation ^Type^ +        -GOTO Functions 
-|Albireo |732 |    | |Cygnus     |Visual| +        -Alt Az Goto 
-|Alcor 497 | |    |         |Ursa Major |Spectroscopic| +        -Enter the desired Altitude and Azimuth. 
-|Algol 111 | |    |         |Perseus    |Eclipsing| +        -Click “Set” or hit the enter key.  
-|Almach 73 | |    |gamma |Andromeda  |Visual| +       *Watch the telescope move and make sure you move the dome 
-|Alpheratz |1 |    | |Andromeda  |Spectroscopic| +       *Note: the telescope will start moving after you clicking Set or hitting enterThere is no Go Next Button for Alt/Az postions.  
-|Arcturus |526 |    |Alpha |Bootes     |3rd brightest star in sky| +===Observing=== 
-|Bellatrix |201 |    | |Orion      |No| +==Initializing:== 
-|Betelgeuse |224 |    | |Orion      |Spectroscopic| +  -Send the scope to a bright star close to the zenith. 
-|Capella |193 |    | |Auriga     |Spectroscopic| +  -Using the paddle, center the star in the finder scope. 
-|Castor 287 | |    |         |Gemini     |Visual| +  -Center the star in the eyepiece using the finderscopes and paddle 
-|Gamma Leporis |217 |    | |Lepus      |yellow and red| +  -In the “Actions” menu under TCS-NG-INDI Click “Init Next”. 
-|Dubhe 417 | |    |         |Ursa Major |Visual| +     *Don'Click “Init Commanded” unless you are a very experienced user! 
-|Iota Cancri | |80416|Iota |Cancer     |Visual***| +==Focus:== 
-|Mintaka |206 |    | |Orion     |Eclipsing| +  *Focus is achieved by looking through an eyepiece and adjusting it using the paddle.  
-|Mirach 42 | |    |Beta |Andromeda  |          | +==Limits:== 
-|Mizar 497 | |    |         |Ursa Major |Visual| +  *For this telescope there is no autodome function. Because of the design of the dome and telescope you need to keep good eye on where the scope is in relation to the domeThere are many situations where the scope can run into the dome. 
-|Polaris |907 |    | |Ursa Minor |Inferred| +  *Currently there is no indication (flashing etc) on the TCS screen that you have hit a limit or that you have run into the dome.  
-|Pollux 295 | |    |         |Gemini     |No| +==Catalogs:== 
-|Procyon |291 |    | |Canis Minor|Visual (but don't bother)| +  -Selecting a catalog 
-|Rigel 194 | |    |         |Orion      |Visual (very nice, almost looks like a quad)| +    -In Xephem Main Window 
-|R Leporis | |150058| |Lepus      |"Drop of blood" red star| +      *Data 
-|Sigma Orionis | |132406|Sigma |Orion      |Gravitational nonuple system, can see 7 easily - awesome!!| +      *Files 
-|Saif 209 | |    |         |Orion      |No| +      *The Files window will pop up you can add catalogs in the “Files” menu and remove them with the “Delete” button. 
-|Spica 498 | |    |  +  -Catalogs in list form 
-|Sirius 257 | |    |         |Canis Major|Visual (but don't bother)| +    -In Xephem Main Window  
-|Tsih 32 | |    |Gamma     |Cassiopeia | +      *Data Menu 
-|Vega 699 | |    |         |Lyra     |Freaking bright star| +      *Index 
-|ghost of jupiter|NGC 3242|   | |           |planetary nebula| +      *The Index window will pop up. You can select an object by name. 
-|37 NGC 2169|| |    | |           |open cluster| +      *If you click Telescope GoTo the “Next” coordinates will be populated in the Indi Panel. 
-|epsilon lyrae |67310 |    |         |Lyra       |double double system| +      *You can then click Go Next to move to that object 
- +      *To use the search function, you must type in the name of the object exactly or it will return no results
-====Questions or Suggestions==== +
- +
-If you have any questions or suggestions for changing the GUI email Scott Swindell <sswindell@as.arizona.edu>. [[21 inch:suggestions|Here]] is a list of suggestions we have already received +
  