21_inch:lightning_shutdown [2013/04/09 12:20]
admin created
21_inch:lightning_shutdown [2016/09/19 14:51] (current)
joe
Line 1: Line 1:
 +=====Lightning Shutdown=====
  
-=====Shutdown===== +  -Follow the steps in the [[21_inch:normal_shutdown|Normal Shutdown]] section
- +  -Unplug blue rack from wall west of operators table
-  -Using GUI move telescope to finder scope access position and replace the finder scope cover+  -Turn off the main power at the two white breakers on the south west side of the building
-  -Using GUI move the Telescope to stow position +
-  -Close telescope cover +
-  -Use remote paddle to line dome shutter with eastern wall.  +
-  -Plug in shutter motor +
-  -close shutter using shutter control box. +
-  -Shutdown TCS gui computer.  +
-  -turn off power to telescope drives at the Telescope power box +
-  -switch dome control to local at the telescope power box.+
21_inch/lightning_shutdown.1365535242.txt.gz · Last modified: 2013/04/09 12:20 by admin